WIRELINE UNIT REQUIREMENTS
Unit
- Minimum pull capacity :
- Slickline, 0.108â€, 0.125†- 80% of breaking strength
- Braided/electric cable, 3/16â€, 7/32†- 80% of breaking strength
- Braided/Electric cable, 5/16â€, 15/32â€, 1/2†- 5 tons
· Minimum wire length capacity 1.5 times expected operational depth or 5,000 m (16,400 ft)
· Drop protection above the cabin
· Splint safe windows
· Double skinned insulated cabin
· Minimum one (1) extra seat
· All electrical equipment zone 1 certified
· Spooling device or back-up drum
· A brake system with minimum capacity equal to cable breaking strength
· Hydraulic drive system capable holding the load in neutral position
· Minimum jarring requirements :
- Slickline drum with 200 kg (440 lbs) tension: Cable speed after 4m acceleration: 3 m/s
- Braided line drum with 1000 kg (2200 lbs) tension: Cable speed after 4m acceleration: 1 m/s
· Logging speed range requirements - all size cables :
- Low speed: 90 m/hr (295 ft/hr) constant logging speed at outer diameter of drum
- High speed: 3000 m/hr (9,840 ft/hr) constant logging speed at outer diameter of drum
Instrumentation
Be located such that operator at all times can read:
· Depth
· Tension
· Cable speed
Depth indicator system
· Calibration range of +/-1.5 m for a depth of 5,000 m (+/- 4.9 ft for a depth of 16,400 ft )
Weight indicator system
· Calibration accuracy of 0.5%
Additional for logging unit
· Supplied with a slip ring collector certified for zone 1
· Automatic overpull shut-down system
Sheave & Hay pulley
· Minimum sheave diameter:
- Slickline, 0.108†- 0.36 m (14â€)
- Slickline, 0.125†- 0.36 m (14â€)
- Braided/electric cable, 3/16â€, 7/32â€, - 0.36 m (14â€)
- Braided/electric cable, 5/16†- 0.48 m (19â€)
- Electric cable, 15/32†- 0.53 m (21â€)
- Electric cable, 1/2†- 0.56 m (22â€)
· Load limit (LL) requirement for sheave & hay pulley: Maximum line pull x 2 x SF
· Minimum safety factor (SF): 2.
· All locking devices to have a double safety feature
Wireline and fishing clamps
· Two (2) for each line size
· Load limit (LL) requirement: Line breaking strength x SF
· Minimum safety factor (SF): 2
· All locking devices to have a double safety feature
Hydraulic power pack:
· Diesel engine certified for Zone 2 or electric motor certified for Zone 1
· A gas detector with an audible/visible alarm installed on air inlet of diesel engine
· Drip pan
· Manual ESD function.
· ESD panel loacted in a safe area Data Acquisition system:
Pressure test pump:
· Working pressure 345 bar (5,000 psi) / 690 bar (10,000 psi) / 1034 bar (15,000 psi) as required.
· Pump rate:
- 50 l/min at 69 bar (1,000 psi)
- 8 l/min at 345 bar (5,000 psi), 5 l/min at 690 bar (10,000 psi) and 1034 bar (15,000 psi)
· Fluid tank: 1000 liter
· Pressure recorder included
Wellhead pump:
· Working pressure 345 bar (5,000 psi)/ 690 bar (10,000 psi) / 1034 bar (15,000 psi) as required
· Minimum two (2) separate pumps included in skid
· Check valve on return line to fluid reservoir