Why there is no upper limit for the dissolution in IR products?

Why there is no upper limit for the dissolution in IR products?

IR, which stands for immediate release, is a term you've likely come across if you've ever delved into the intricacies of pharmaceutical manufacturing. You may have noticed that IR products have dissolution specifications, typically expressed as not less than a certain percentage, often around 75% or 80%. These specifications also include time limits, usually within 15, 30, or 45 minutes.

Now, the purpose of dissolution testing is not to determine the potency, as it would be in the case of an assay. Instead, dissolution specifications incorporate a time factor. This means that the process is time-dependent, as evidenced by the inclusion of a time limit, such as 45 minutes.

Simply put, the less time it takes for the dissolution to occur, the lower the dissolution percentage, while a longer timeframe yields a higher dissolution percentage, approaching 100%. However, there's a fascinating twist to this story.

To achieve a discriminating dissolution test, it's preferable to use a dissolution medium with low solubility (keeping in mind that the medium does not become a rate-limiting step). This aspect is crucial in understanding why there's no upper limit for the dissolution of immediate-release dosage forms. But why is low solubility in the dissolution medium so vital?

Low solubility in the medium is advantageous because it enhances discriminatory power. Discriminatory power is a key characteristic of any dissolution test procedure, as it helps distinguish between different formulations and manufacturing processes.

While using a medium with low solubility is generally preferred, you must also ensure that the sink condition is met and that the dissolution medium itself doesn't become the rate-limiting factor. In other words, the dissolution medium should not hinder the release of the drug product, as it could lead to inaccurate results.

Therefore, the medium with the lowest solubility for the drug substance is the preferred choice for dissolution testing. This approach maximizes the discriminatory power of the test method. In essence, dissolution testing, by design, biases towards limiting the rate of release to achieve the necessary discrimination, making an upper limit unnecessary.

In this light, it becomes clear that dissolution testing is inherently biased to limit high drug release. Hence, the discussion revolves around lower limits, such as not less than 70% or 80% of the quantity (Q). The intent is always to strive for higher drug release.

To put it into perspective, think about the specifications for related substances. These specifications have lower limits for impurity but never have upper limits, usually due to the design of drug manufacturing, which aims to eliminate or minimize related substances.

This philosophy extends to dissolution testing for immediate-release dosage forms. While modified-release dosage forms have both lower and upper limits at specific time points, immediate-release products do not. The focus is always on achieving optimal and consistent release, not a maximum release.

However, there are situations where erratic dissolution results, such as 200%, might occur. In such cases, it's essential to investigate the root cause. Dissolution values greater than those found during the uniformity of dosage unit test must be explored, as they point to factors beyond manufacturing process variability.

In essence, understanding the complexities of dissolution in immediate-release products reveals that the lower limit is the only concern. The design of the dissolution method naturally discourages high drug release, making an upper limit irrelevant. This showcases the meticulous and precise nature of pharmaceutical quality control, ensuring that each medication you take is consistent and safe.

?What is your thought? Please do share…

Gurudatt Hendge

Research Scientist (ADL) at R&D, Zuventus Healthcare Ltd (Emcure group), Pune

1 年

Thanks Sir for clarifying purpose of Dissolution test in detail.

回复

要查看或添加评论,请登录

Bhaskar Napte ~ Pharma Coach的更多文章

  • pH, pKa, and Retention

    pH, pKa, and Retention

    1. Introduction: In the world of chromatography, understanding the impact of pH on the retention of polarizable or…

    2 条评论
  • Why use tapers in GC liners?

    Why use tapers in GC liners?

    Greetings and welcome! I'm Bhaskar Napte from Pharma Growth Hub, and today we're delving into the world of tapered GC…

  • Why does GC inlet liner have a hole?

    Why does GC inlet liner have a hole?

    Today we'll delve into the intriguing world of Gas Chromatography liners and their unique features. In particular…

    1 条评论
  • Phenyl Column Mystery

    Phenyl Column Mystery

    Today, we delve into the fascinating world of stationary phases, particularly focusing on the versatile PHENYL column…

    1 条评论
  • UNDERSTAND OOS IN 10 MINUTES

    UNDERSTAND OOS IN 10 MINUTES

    Let us dive into a topic that holds significant importance in the pharmaceutical industry: Out of Specification, or OOS…

    2 条评论
  • EMA's Latest Guidance on Nitrosamine Impurities: Which limits apply to Nitrosamines in medicinal products?

    EMA's Latest Guidance on Nitrosamine Impurities: Which limits apply to Nitrosamines in medicinal products?

    Introduction: Greetings! In a recent development, the European Medicines Agency (EMA) has made significant revisions to…

  • Why Method Validation? Which parameters are to be performed during method validation?

    Why Method Validation? Which parameters are to be performed during method validation?

    Just imagine you are at the traffic signal and suddenly the traffic lights stop functioning. You can imagine what havoc…

    3 条评论
  • HOW TO PERFORM ACCURACY DURING METHOD VALIDATION?

    HOW TO PERFORM ACCURACY DURING METHOD VALIDATION?

    As per ICH guideline Q2(R1), the accuracy is defined as below “The accuracy of an analytical procedure expresses the…

    16 条评论
  • HOW TO PERFORM LINEARITY DURING METHOD VALIDATION?

    HOW TO PERFORM LINEARITY DURING METHOD VALIDATION?

    As per ICH guideline Q2(R1), linearity is defined as below, “The linearity of an analytical procedure is its ability…

    8 条评论
  • HOW TO PERFORM PRECISION DURING METHOD VALIDATION?

    HOW TO PERFORM PRECISION DURING METHOD VALIDATION?

    As per ICH Q2(R1), precision is defined as below, “The precision of an analytical procedure expresses the closeness of…

    3 条评论

社区洞察

其他会员也浏览了