Why HPSV & Tube-lights in any Plant / Industries which are running 24 x 7 should be replaced with LED lights ?

Dear Friends

Everywhere in India concentration is placed on use of effective & efficient energy systems.

My previous mails regarding benefits of HPSV lights vs LED lights have given you details regarding saving that can be made when we replace HPSV or Fluorescent Tube lights with LED Lights. A Quick look at that below

  • A 70 Watt HPSV light should take current around 0.3-0.4 Amp but takes around 0.7-0.8 Amp due to presence of choke with PF around 0.9-0.92 if capacitor is there.
  • An Equivalent LED light for 70 W HPSV is 40 Watt and it takes around 0.18-0.22 Amp with PF 0.98 -0.99 and Lumens more than 70 Watt HPSV. Only difference is color.

Both checked with same clamp meter, Energy meter and Lux Meter.

Same was the Case with 150 Watt, 250 Watt and 400 Watt, HPSV Light. You too can check Current of HPSV lights of 70, 150, 250 and 400 watt and you will know the difference

We changed 70 Watt HPSV lights and 40/36 Watt Fluorescent Tube-lights with 40 Watt LED lights and 20 Watt LED Tube. Our first target was to replace all those lights which are running 24 x 7 so to get faster Payback and savings

Now how this is beneficial for those industries who are taking power from Grid and Paying Demand charges

Suppose you replace 100 Nos 70 W HPSV with 100 Nos 40 W LED lights and 200 Nos 36 W Tube-light with 20 W LED rod, which are running 24 x7.

So Direct saving is 30 Watt X 100 = 3 kW and 16 Watt x 200 Nos = 3.2 kW means reduction of 6.2 kW or say 6 KVA demand.

As the number of replacement increases demand comes down and so the savings, Suppose your demand come down by 5 KVA and per KVA demand is rs around 300 per KVA, means saving of around Rs 1500 Per month and around Rs 18000 per year.

Payback period for LED light is around 1.5 years and 2.7 years for 24 x7 and 12 x 7 respectively

I wish every Electrical Engineer got the idea how to save energy and reduce your electricity bill.

Now if your plant purchase a lot of LED lights they can get Lights at much cheaper rate than mentioned, As purchase department will be able to negotiate for larger Quantity. Also these LED lights come with 3-5 Year warranty.

Locations where replacement with LED will benefit industries

1)     1.CCR, Admin Offices, Lubrication Room, Load Centres or Substations (Where in Florescent Tube-lights can be replaced with LED Tube light which almost runs for 24 X 7 Hour. 36 / 40 Watt can be easily replaced with 20 Watt)

2)     2. Cable Cellar and Transformer Room

3)     3. Enclosed Room like Compressor rooms, Electrical or Mechanical Workshop, or any enclosed room (Packing Plants, etc)

4)     4. Inside Silos (Silos is used for storing semi-finished or Finished material)

 Many Benefits of LED Lights apart from Load reduction are as below:

1)     Reduction of Lighting Load with same lumen (i.e 70 Watt HPSV = 35-40 Watt Led, 150 Watt HPSV = 70-80 Watt LED, 250 Watt HPSV = 120-150 Watt LED)

2)     Reduction of Current Due to less wattage and non use of Choke, Ignitor and Capacitor, hence reduction of Copper loss I(Sqr)X Resistance

3)     Reduction of KVA requirement of lighting transformers due to Point 1 &2

4)     Reduction of Maintenance cost due to non use of Choke, Ignitor and Capacitor which is mostly required to be changed after every 2 year. Also LED gives guarantee of 3-5 years depending on Manufacturer

5)     HPSV light is hot light if it is on for more than 10 - 20 minutes you will not be able to touch it as it produces heat, But LED is cool light. Hence saving Environment.

6)     Reduction of Running Cost, which will lead into Reduction in KWH / Tonne of finished product

7)     Minimum effect with Fluctuation of Voltage, as LED Lights work at Voltage Range from 90 – 300 Volts, reducing their failure chances.

8)     Lesser harmonics in Power System due to non use of Choke, Ignitor & Capacitor in HPSV lights.

Regards

Avinash Singh

Neranjan Rathnayake

Chartered Electrical Engineer | Associate Professional (Green Building Counsil - SL) | AM(SLEMA) | Electricity Distribution (Utility), Network Planning, SCADA , Solar PV, Offgrid/Hybrid Power| IT (Network & Security)

6 年

Good article with experimental results. Most people do a mistake by selecting unbranded / generic inferior LED products available in open market. The efficacy of these LEDs are often lower and lifetime of drivers are limited to few months. This kind of replacement might not give good payback for the customer as he looses the reliability of lamps [need to be changed frequently] and has to spend more for replacements. Therefore, considering the warranty, reliability and quality of these new LED lamps IS A MUST.

回复
Eronildes Santana de Oliveira

Diretor na Eronildes Santana de Oliveira ME

6 年

Three years ago, here in the city of S?o Paulo, the fluorescent lamp posts were replaced by Led lamps. Only they were overpriced in more than 20 million dollars. The economy generated in lower consumption of electric energy, maintains the high rate that the consumer picks up by the corruption. The replacement of the other lamps by LED is an alternative for individualized cases, such as companies, residences, offices, agricultural companies, and places and people who need light for private use, eg a family uses led lamps to illuminate residence , the garden, the fish pond. in this example it can achieve an economy in the use of the led lamp in relation to the fluorescent lamp or another lamp that consumes more energy than Led. ?

回复
раяам desai

Deputy Manager [Plant Utility] at TOTO India Industries Pvt. Ltd.

8 年

Obviously LED's are the best replacement for conventional lights in terms of life, saving & performance. Moreover, if you add motion sensors for control of this LED's in offices, washrooms, break rooms,etc you get additional saving and quick payback! It will be like adding a cherry on the cake! ??

Bonny Benny

Data Analytics & Product Management | SAFe Certified Product Owner | MSc Business Analytics | Former Senior Analyst - EY | ETL | Alteryx | SQL | Python | Power BI | Tableau

8 年

@prasad if you find the answer to your question please let me know.

回复
Prasad Gore

Power Quality Consultant at Electrical Science Solutions

8 年

What Are drawbacks or disadvantages of LED in terms of its operations and its effects in entire power quality.

要查看或添加评论,请登录

社区洞察

其他会员也浏览了