Why do I have to use double glazing and they don't?
Whether you’re a builder, architect or homeowner, this may be a question you have asked yourself during the course of your project.?I’ve heard it before and the other Friday when I was at the Pro Clima installation training day in Mount Gambier, in our post demo chit chat, one of the builders piped up.?His question and I’m paraphrasing, is below:
I’ve had to build with 120mm studs to get more insulation in my walls, double glazing, roof blanket… but the bloke next door has single glazing, 90mm studs etc… how??
It’s a great question and below are a few possible reasons I gave.
Individual simulations
The thermal performance requirements and resulting specifications of a home depend on many design features of your project.?Each house has its very own energy assessment and is assessed on its own merits.?For example, large houses with larger windows and the main living area facing south may, or rather definitely will, require a different specification than smaller houses with smaller windows with the main living area facing north.?The main things that impact the energy efficiency specification are as follows:
Other things matter too, for example wall construction, whether you have an elevated floor or a concrete slab, shading etc.?But typically in my experience, the above list are the biggest ones.
Did they use the same assessment method as you?
The most commonly known method for doing an energy assessment is a star rating and sometimes there is a misconception that this is the only way to obtain energy compliance.?There are in fact four ways to obtain energy efficiency compliance in Australia.?See below for more information. (Note: there are state variations)
2. Verification against a Reference Building
领英推荐
3. DTS – Deemed to Satisfy
4. Performance Solutions
The intent is that these four methods produce buildings that perform thermally to a similar level, however in my experience, they produce four very different outcomes.?
Material Exchange
Builders going rogue on what is on the plans is not uncommon.?The reason a builder might choose a different window, for example, is usually dependent on issues such as cost, supply issues, last-minute design changes by the client or sometimes, simply what is easiest.?This happens all the time in the residential sector in particular and if the house isn’t likely to fall down or burn down, any other non-compliant issues go more or less unchecked.?
On a different, but related note, have you ever seen a “by owner after handover” specification? This is usually noted in relation to ceiling fans, floor coverings, or external window shading.?If these are noted on the plans, these items are modelled but may or may not be installed.?Each have an influence on the outcome of the assessment.
Energy Assessor skill / integrity
Just like in every other profession, there are differing levels of skill and honesty in energy assessors and it’s almost impossible to tell from your energy report unless you know what you’re looking for.?Most assessors do the right thing, and star ratings are audited from time to time, however energy assessments are complex.?The technical notes that govern how star ratings are modelled can be open to interpretation.?I can’t count the number of times I have pulled up and studied the tech note and been so grateful for the team of people who were around me who help me interpret.?There are a number of assessors out there who don’t have that support and therefore must push through on their own.?Verification Against a Reference Building is incredibly complex.?The glazing calculator can be very tricky.
The energy efficiency section of the building code is a complex beast.?It is well acknowledged in the building industry that there can be a fair difference between was is designed, what is modelled and what is built (known as The Performance Gap – this is another lengthy discussion in itself).?So to summarise, if your neighbour is using single glazing and you have to use double glazing, it’s likely that the reason could be one of the following:
Having said all of this, it’s really important to understand that windows are the weakest point of your building envelope.?This is where you will lose and gain most of your heat and installing high-quality windows is the best thing you can do for your future thermal comfort, so whether your energy assessment says you have to or not, it's worth thinking about. In addition, as building code requirements increase, double glazing will become more and more common all over the country, not just in cold climates.
If you have further questions about energy efficiency, condensation management or air tightness, drop me an email or head to our website www.climasure.com.au and sign up to our mailing list.?We never spam, promise.
Hope to talk soon!
Jess
ATTMA Scheme Manager for Australia & New Zealand
2 年Good outline of the answers to this common question
I help architects design healthy, comfortable, and resilient homes for their clients
2 年From our review of each compliance method so far, NCC 2022 has done a good job at aligning the outcomes of each.. time will tell!
Builder at Ionic Construction
2 年Hopefully change is in the air sooner rather than later Jessica Allen. ?? With the increase to 7 star in NCC 2022, high performance windows may become one of the easeist pathways to compliance in many scenarios.
Director/Builder/Energy Rater at Positive Footprints
2 年I believe NCC 2022 seeks to realign the various pathways through the code, so hopefully there will be less of a potential loophole there for lower spec compliance when that comes in. In fact I think in many climates you will find that NatHERS (being a performance based pathway) may allow a better design to spec lower in achieving the 7 star requirement. Glazing area vs floor area is also a determining factor. While you may get away with single glazing in a particular location if you keep your glass area ratio down, a house that has large glass areas will need double glazing to get across the line. As others have said, windows are the weakest link. This is doubly true if you have big glass areas that don't get much northern solar gain... And one last issue to highlight are unaccredited raters. Raters who are accredited by joining Design Matters National or ABSA or equivalent body must do 12 points CPD every year and get random work checks. Unaccredited raters are working with no oversight so who knows if they keep up with changes or are accurate in their data entry? I'd always advise asking your assessor to show proof of being accredited. Anyway, great post Jessica!
President at Quik-Therm Insulation Solutions Inc.
2 年Because there is less energy loss with a sealed air space between two panes.