When is the right time for pregnancy? How to predict the best ovulation time?
When is the right time for pregnancy??
Women only ovulate once a month, and only a few at a time. If you can accurately calculate the time of ovulation, it is very beneficial for pregnancy.
Now we are going to find out what time is the best time to detect ovulation.
1. In each menstrual cycle of women, the luteinizing hormone (LH) in the urine will peak within 24-48 hours before ovulation. The use of ovulation test strips can accurately detect the peak level of LH.
2. The best detection time for ovulation test is from 10 am to 8 pm:
Use a clean and dry container to collect urine. The best time to collect urine is from 10:00 am to 8:00 pm. Try to use urine samples at the same time every day. Water intake should be reduced 2 hours before urine collection, because Diluted urine samples can prevent detection of LH peaks.
How to predict the best ovulation time?
Accufast brand new patented ovulation peak test with 6 lines can predict ovulation after about 6 hours by catching T4 line.
What is semi-quantitative?LH ovulation peak test?
LH (Luteinizing Hormone),?A hormone that regularly changes during a woman's menstrual cycle, its role is to stimulate the release of mature eggs in the ovaries.
During the ovulation period of women, the secretion of LH increases sharply, and ovulation can be triggered within 1-2 days after the coming?of the "LH peak". Semi-quantitative ovulation?peak test?is?used for?the detection of luteinizing hormone (LH) levels in the urine to grasp?the time of ovulation.
Generic Name:?One Step Semi-Quantitative LH Urine ovulation Test (Colloidal Gold Immunochromarographic)
Luteinizing Hormone (LH) Test Strip (Colloidal Gold Immunochromatographic) adopts the principle of Immunochromatographic sandwich method and is used to determine the LH content in human urine by semi-quantitative method.
How to use it and how to read the result?
A physiological cycle is from the first day arrival of menstruation (bleeding day is the first day) to the day prior to the next menstruation. The Initial Test Date can be determined according to the Test Timetable below and the test should be repeated continuously for 5-7 days.?
Note: Determine the Initial Test Date according to your physiological cycle. If your physiological cycle is uncertain, determine your Initial Test Date based on days of the shortest physiological cycle. In this case, additional 6 day test will be needed. If your physiological cycle is less than 21 days or more than 41 days, please consult the doctor for advice.
领英推荐
【Test Method】
l.Stand the test and sample to the room temperature.Then unseal the aluminum foil pouch along its incision, and take out the midstream.
2.The midstream has two viewing areas.The left side are quality control line C and test lines T3 & Tl.On the right side are quality control line C and test lines T4 & T2.
3.Hold the test stick, pointing absorbent tip(sample well) downward and place it in your urine stream for about 10-15seconds. You can also collect your urine into a clean cup (not provided) and dip the sample well into the urine for about 10-15 seconds.
4.Read the result at 5 minutes.
5.The results showed no clinical significance after lO minutes.
【Test Result Interpretation】
The negative result consists of three situations as below:
a) When only the quality control line C appears color, LH concentration<1 mIU/mL indicates it is beyond the ovulation period.
b) When the quality control line C and the test line T1 appear color, 1 mIU/mL≤LH concentration <5 mIU/mL indicates it is beyond the ovulation period. If the above mentioned test results occur for several days, it may be due to the hypogonadotropic?hypogonadism, which commonly appears in Sheehan's syndrome. Consult the doctor for advice.
c) When the quality control line C and the test line T1&T2 appear color, 5 mIU/mL≤LH concentration<25 mIU/mL indicates it is beyond the ovulation period.
The positive result consists of the two situations as below:
a) When the quality control line C and the test lines T1,T2 and T3 appear color, 25 mIU/mL≤LH concentration<65 mIU/mL indicates it is within the ovulation period.
b) When the quality control line C and the test lines T1,T2 ,T3 and T4 appear color, LH concentration≥65 mIU/mL indicates it is within the ovulation period.
If the LH peak results occur for several days, pregnant test should be done first. Otherwise, it may be due to the ovarian dysfunction.?See you doctor for advice as soon as possible.
Invalid
When the quality control line C doesn’t appear color, it indicates the test is failed or the product is invalid. Change the product for retest. If the issue is still exist, stop using this product and contact the local distributor.?
After the test, evaluate the LH content value within a reasonable range and record each LH content value on the record card. Connect all the value points to form a LH content curve. Till a complete LH peak appears, the ovulation will occur within 6-12 after reaching the peak value.