When Opportunity Knocks, Build a Data Center
Building and operating a data center today – regardless of whether the site is enterprise owned, a collocation/multi-tenant site, cloud hyper-scale or edge – is more challenging than ever. Equipment continues to be more compact and powerful, and compute utilization varies widely with workload. The result is higher density footprints demanding a varied and wider range of power and cooling support.
We at iSolutions help you with planning, design and installation of large and small data center solutions. We ensure a solution that best fits your business. We have extensive experience in both small and large installations in the Middle East region.
Raised Floor
Raised floor systems, also known as access floors, are an elevated structural floor that is stabilized over a solid substrate, typically a concrete slab. A raised floor system creates a gap ideal for running electrical wiring and HVAC ducts.
No matter how large or small your project is, iSolutions experts can provide cost-effective options in configurations that fit your needs. Let us provide you with design analysis recommendations and optimize your underfloor cable trays to maximize space and handle high head loads.
Advantages of a Raised Floor
- Raised Floors helps in Future Scalability
- Enhanced cooling Capabilities and Control
- Flexibility to Incorporate Energy Efficient Design Opportunities
- Easily Adapt to Technological and Client Changes
- Allows for Separation of Water, Power and Cable.
- Ability to Terminate Cables Where You Need To
- Reduced Operating Costs and Lower Facility and Maintenance
Costs
- Underfloor Service Distribution Space Keeps Interior Space
Clean and Neat
Cabinet
Intelligent Data Centers Start with Intelligent Racks.
When it comes to racks management solutions. We offer a vast array of intelligent rack solutions that improve the management and maintenance of critical IT equipment, resulting in increased efficiency and uptime.
领英推荐
Looking for server racks a bit more customizable? We can design the server racks enclosure or cabinet you've always dreamed about and get it to you in a few weeks. From micro design airflow cooling issues to macro data center design and deployment, we've got the expertise to make your ideas a reality while installing flexible solutions for continued growth.
Fire Fighting
We understand the challenges of fitting gaseous fire suppression systems into areas housing sensitive equipment and where business continuity is a critical factor. With the need to protect such assets, a reliable solution is required. Our response is twofold: time-proven agents that leave no residue and are safe for the protected equipment. Our systems may help reduce footprint, complexity, and the size of the pipe network. In short, our technology expands system flexibility, enabling engineers to accommodate gaseous fire suppression systems in a less obtrusive way while addressing the specific requirements of a protected area.
While doing data center design, iSolutions makes adequate arrangements to protect hardware and data of data center from any force majeure conditions like fire, flood. At iSolutions, We supply fire suppression systems that are equipped with specialized FM200 gas. Environmentally friendly and non-toxic, FM200 poses no risk to human health and no significant reduction in oxygen levels. FM200 gas is effective within 10 seconds of discharge so that fires are rapidly extinguished before they spread.
In from Precision Cooling
Conventional data center cooling floods an entire room with cold air-an approach that works well at minimal power densities. In-Row cooling offers capacity and efficiency gains by moving the air conditioner from the perimeter of the room closer to actual load. Installed on the floor or suspended from overhead, in-row cooling units provide local, focused cooling at the rows of server cabinets which fill the data center.
Distance is the cornerstone of inrow performance. Neither cool air nor warm exhaust air has far to travel, allowing the unity to dissipate high heat loads. Flexible Cooling Medium Inrow solutions, whether floor mounted or overhead, consist of fans and a cooling coil. Depending on the product, the cooling coil will utilize chilled water or refrigerants as the cooling medium.Refrigerant based units will require connection to a remote condenser system while chilled water based units traditionally connect to chiller systems.
- Adapts to all major manufacturers racks and rack containment systems.
- Suitable for new and existing data centers; easy to add units as you grow.
- Used in containment, open architecture and hot spot reduction applications.
Integrated Cooling
An integrated cooling system features the cooling unit inside the base of the rack. It is the most precise cooling available, as the rack and the air conditioner operate in a closed relationship with one another. Cold air has no choice but to pass through the servers and the hot air has no choice but to pass through the heat exchanger. Integrated cooling provides a computing environment that is thermally neutral to the rest of the room. These integrated solutions typically can only cool up to 3kW and are designed for small IT rooms and network rooms.
- Adapts to all major manufacturers racks and rack containment systems
- Installation on raised / non-raised floors
- Suitable for new and existing data centers; easy to add units as you grow
Get in Contact with our experts ! https://www.ismena.com/contact-us/