What is the vibration of the ultrasonic cleaner?
Ultrasonic cleaning machine may have some conditions during use. For some simple problems, it can be eliminated by yourself. If it is really bad, it can only be sent back to the original factory for repair. The problems that occur in ultrasonic cleaning machines are small problems, and most of them can be easily solved by themselves. If problems occur first, you need to carefully check them out. Don't be too nervous. If you really don't understand it, I hope that you don't want to repair it blindly. You need to ask a professional staff for repair. So how do customers eliminate the general problems of ultrasonic cleaners?
First: the ultrasonic cleaner does not work - can not boot
First of all, we should check whether the power supply is connected. Many customers have not connected the power supply. They think that the machine is not working and can't open the machine. The result is OK under the guidance of our technicians. According to our statistics, more than 60% of the problems that are not turned on are that the power supply is not connected. Checking the power supply is very simple. You can plug other electrical appliances into the original jack to see if it works. If it can't, it means that the power supply is not connected.
Second: the ultrasonic cleaner does not work - the power indicator is not lit.
Some machines are used for a period of time, suddenly do not work, the power indicator is not lit, after the power is removed, if the light is still not bright, you can pull out the insurance of the machine, or directly change one root. Most of the ultrasonic cleaning machines are equipped with spare insurance, and they are replaced. Note: Please do this after disconnecting the power.
Third: the ultrasonic cleaner does not work or has no vibration
After the machine is plugged in, it can be turned on, the indicator light can be on, but the liquid in the cleaning tank has no signs of vibration. If it is mechanically controlled, you can check whether the knob switch that controls the ultrasonic wave is turned on or adjusted to the time position. The CNC ultrasonic cleaning machine should check whether there is a press and the timing is set. If the two items are excluded, it can be judged that there is a problem with the internal components of the machine, and it can be sent to the factory for repair. If the customer has some experience in electronic maintenance, they can also dismantle them and find out the problem areas.
Fourth: Ultrasonic vibration becomes smaller:
1. Line virtual welding: The ultrasonic vibrator circuit is connected in series. If there is any de-soldering and oxidation phenomenon, it is necessary to add tin re-welding. In addition, it can be glued with glass glue or the like.
2, degumming: long-term high-temperature cleaning, ultrasonic vibrators may have degumming, need to re-stick vibrators.
3, the age of use: long use time, transducer aging, performance degradation, maintenance methods can increase the ultrasonic power, but this method will cause the heat of the transducer to increase, can not solve the problem, it is recommended to replace All transducers.
4. Transducer problem: Some transducers are damaged, and the bad transducers are replaced with the matching transducers.
5, circuit board damage: ultrasonic generator too much dust, or damp, resulting in some circuits are not smooth, need to clean the inside of the ultrasonic generator, it may be that the shock plate is too thin, long-term use, there will be shattering and shaking phenomenon, resulting in Ultrasonic shock plate water damage to the circuit board, need to contact the manufacturer for maintenance.
6, the cleaning machine working environment, such as the type of cleaning agent, cleaning temperature, liquid level and other effects.
7. Ultrasonic attenuation caused by other unknown conditions, such as the way of cleaning materials and the replacement of cleaning agents.
In short, the ultrasonic vibration becomes smaller. Generally, the transducer appears. If the transducer is not faulty, then the ultrasonic generator has a problem. You can check whether the components inside are broken.