What are Nitrosamines in the Pharmaceutical Industry ?
Sagar Pawar
Quality Assurance | Validation | Computerized System Validation (CSV) | GAMP 5 | Complaint Investigation/Post Market Surveillance (PMS)-Medical Devices |
Follow this link to read the full article: https://zamann-pharma.com/2024/06/17/what-are-nitrosamines-in-the-pharmaceutical-industry/
What are nitrosamines?
Nitrosamines are chemical compounds classified as probable human carcinogens, meaning they can potentially cause cancer. They form through a chemical reaction between nitrites and secondary amines, which are found in various industrial processes, including the manufacturing of pharmaceuticals.
The introduction of nitrosamines into pharmaceutical products can occur at various stages of the drug development and manufacturing process. One primary route is through the synthesis of drug substances. Specific reactions or conditions during the manufacturing process can facilitate the formation of nitrosamines. Additionally, contamination can arise from raw materials, intermediates, or even the final drug product if they come into contact with nitrosating agents. Another potential source is the degradation of certain drug substances over time, leading to the formation of these impurities. Cross contamination during production, storage, or transportation can also contribute to the presence of nitrosamines in drug products.
While there is a very low risk that nitrosamine impurities could cause cancer at the levels found in drug products, individuals may be at increased risk if exposed to nitrosamine impurities at above acceptable levels or over long periods of time. The detection of nitrosamine impurities in several commonly prescribed medications, including antibiotics, antacids, and antidiabetics, rapidly resulted in the recall of these drug products. Consequently, many patients worldwide faced temporary interruptions in their treatments.
Now, mitigating nitrosamine contamination is at the top of global regulatory priorities for the pharmaceutical industry, with the US Food and Drug Administration (FDA) and European Medicines Agency (EMA) making it a legal obligation for drug manufacturers to present their reformulation and risk mitigation plans
What industry should know about nitrosamine impurities?
Manufacturers are responsible for understanding their processes, which includes preventing the presence of unacceptable impurities. Manufacturers are also responsible for developing and using suitable methods to detect and limit unacceptable impurities, including any new impurities that may arise when they make changes to their manufacturing processes.
FDA has published testing methods that can be used by industry to detect nitrosamine impurities.
FDA, in collaboration with regulatory counterparts around the world, has set internationally recognized acceptable daily intake limits for nitrosamines. If drugs contain levels of nitrosamines above the acceptable daily intake limits, FDA recommends these drugs be recalled by the manufacturer as appropriate or not be released for distribution to the market.
The agency is working with industry to determine the source of these impurities, but there are multiple reasons why nitrosamines can be present in medicines.
FDA has provided information to industry on mitigation strategies to reduce the risk of nitrosamine drug substance related impurities (NDSRI) in drug products.
Root Causes of Nitrosamine Impurities in APIs and Drug Products
Nitrosamine impurities in Active Pharmaceutical Ingredients (APIs) and drug products are a significant concern due to their potential carcinogenic effects. The FDA has identified various root causes for these impurities, which can be categorized into process-related factors, supply chain issues, and stability concerns. Below is an elaboration of these factors based on FDA guidelines:
A. Process-Related Causes:
Properties of the Starting Materials, Intermediates, or Drug Substance:
Specific Process Conditions:
Impurities in or Reactions with Raw Materials:
B. Supply Chain Causes:
Use of Recovered or Recycled Materials or Other Intermediates Contaminated with Nitrosamines:
Cross-contamination in Multi-purpose Facilities:
领英推荐
C. Stability-Related Causes:
Stability of Drug Substance or Drug Product:
Excipient Compatibility:
?Regulators strategy and testing requirements
The European Medicines Agency (EMA) and US-FDA guided the review process and started collecting the most common root sources: APIs, impurities, excipients, primary packaging. They could directly carry a nitrosamine but also their precursors (nitrosatable and nitrosating agent) interacting into the final drug product through the shelf life. Regulatory agencies such as the FDA and EMA have provided guidelines to pharmaceutical companies on how to assess and mitigate the risk of nitrosamine contamination in drug products. These guidelines include recommendations on testing methods, acceptable limits, and risk assessments for potential sources of nitrosamines. The European Medicines Agency (EMA) and US-FDA guided the review process and started collecting the most common root sources: APIs, impurities, excipients, primary packaging. They could directly carry a nitrosamine but also their precursors (nitrosatable and nitrosating agent) interacting into the final drug product through the shelf life.
The investigation process prescribed to all Marketing Authorization holders is a three-step approach: Risk Assessment, Confirmatory testing, and Remediation plan.
FDA Recommendations
The?FDA’s final guidance on nitrosamine ?impurities emphasizes the need for thorough risk assessments, sensitive confirmatory testing, and robust remediation plans. This guidance recommends steps manufacturers of APIs and drug products should take to detect and prevent unacceptable levels of nitrosamine impurities in pharmaceutical products. Key points include from understanding of carcinogenic potential of nitrosamines, the FDA advises manufacturers to thoroughly assess and mitigate their formation in Active Pharmaceutical Ingredients (APIs) and drug products. This detailed approach requires the investigation of both established and potential pathways for nitrosamine formation, underlining the need to prioritize assessments based on key factors such as the drug’s dosage, duration of treatment, and extent of patient exposure. In line with these guidelines, if nitrosamines are detected, a thorough investigation must be conducted to determine their origins. Subsequently, necessary adjustments to manufacturing protocols should be made to minimize or eliminate such risks. This process demands a collaborative effort between API (Active Pharmaceutical Ingredients) producers and drug product manufacturers to effectively identify and address risks.
Generally, FDA considers reformulation of an approved drug product a major change requiring a prior approval supplement (PAS).
EMA Recommendations
The European Medicines Agency (EMA) has issued comprehensive guidelines to manage and mitigate the risk of nitrosamine impurities in human medicines. These recommendations are intended for marketing authorisation holders (MAHs) and applicants to ensure the safety and quality of their drug products.
These recommendations by the EMA ensure that pharmaceutical companies take proactive measures to identify, prevent, and control nitrosamine impurities, thereby protecting patient safety and maintaining the integrity of medicinal products in the European market. For more detailed guidance and documentation, companies are encouraged to refer to the EMA’s official publications and resources on their website.
1. Risk Assessment and Evaluation:
2. Confirmatory Testing:
3. Control Strategies and Mitigation:
4. Regulatory Actions and Updates:
5. Communication and Transparency:
Conclusion:
Nitrosamines pose significant carcinogenic risks in pharmaceuticals, prompting regulatory bodies like the FDA and EMA to implement stringent guidelines. These include thorough risk assessments, validated testing methods, and proactive remediation plans. Manufacturers must adhere to these protocols to ensure drug safety and minimize patient exposure to nitrosamine impurities. Continuous monitoring and compliance with regulatory standards are critical to maintaining the integrity and safety of drug products.
Quality Assurance | Validation | Computerized System Validation (CSV) | GAMP 5 | Complaint Investigation/Post Market Surveillance (PMS)-Medical Devices |
5 个月Follow this link to read the full article: https://zamann-pharma.com/2024/06/17/what-are-nitrosamines-in-the-pharmaceutical-industry/