Like Hinge,Mortise lock,Lever handle,there is also a coding system for BS EN1303 Cylinder.Let’s find out what does each digit means.

EN1303/EN1634 Euro profile cylinder


1. Category of use

One category is identified.

Grade 1: For use by people with a high incentive to exercise care and with a small chance of mis-use.

2. Durability

Three grades are identified according to the number of test cycles achieved.

Grade 4 : 25 000 Cycles

Grade 5 : 50 000 Cycles

Grade 6 : 100000 Cycles

3. Door mass

One category is identified.

Grade 0 : No requirement

4. Fire resistance

Two grades are identified:

Grade 0 : Not suitable for fire/smoke resistant door assemblies

Grade 1 : Suitable for fire/smoke resistant door assemblies subject to satisfactory assessment of the contribution of the cylinder to the fire resistance of the specified fire/smoke door assemblies. Such assessment is beyond the scope of this European standard (see EN 1634-1).box 4), it must be possible to demonstrate compliance with the Essential Requirements of the Construction Products(Amendments)Regulations.

5. Safety

One grade is identified:

Grade 0 : No requirement

6. Corrosion and Temperature Resistance

Four grades are identified according to EN 1670:

Grade 0:No corrosion or temperature resistance requirements.

Grade A:BS EN 1670 Grade 3 corrosion resistance (96 hours NSS):no temperature resistance requirements.

Grade B:No corrosion resistance: resistance to -20/+80 C temperature extremes.

Grade C:BS EN 1670 Grade 3 corrosion resistance: resistance to -20/+80C temperature extremes.

No distinction is made between the inside and the outside of either the cylinder and/or the door. On completion of the test, the cylinder must operate

7. Key related security

Six grades are identified and the principal requirements are summarized as below :

图片无替代文字

8. Attack resistance

Three grades are identified and the principle requirements are summarized as below:

图片无替代文字

In next share,we will introduce some normally seen Key management function like "Keyed to Differ","Key Alike","Common Entrance","Master key/Grand Master key/Great Grand master key","Construction key".

D&D hardware is ISO certified manufacturer specialize in BS EN,ANSI.BHMA,UL certified door hardware.We have rich experience working with Brands,Door factories,Projects.OEM service is welcome.(produce under your brand)

图片无替代文字