WASTEWATER TREATMENT UNIT TO REMOVE HEXAVALENT CHROMIUM AND OTHER HEAVY METALS

WASTEWATER TREATMENT UNIT TO REMOVE HEXAVALENT CHROMIUM AND OTHER HEAVY METALS

Wastewater Treatment Unit. The process line for wastewater treatment from chromium, lead, nickel, iron and other heavy metals can be equipped with the AVS-100 (150) electromagnetic nano-mill by GlobeCore. It significantly reduces reagent consumption, provides better cleaning and make the process continuous.

The main feature of the electromagnetic nano-mill is the intensive mixing of materials with the help of ferromagnetic particles affected by an electromagnetic field. The impacts and friction of the particles against each other, the walls of the chamber and the material forms colloidal metal, which is an excellent reducing agent. Simultaneously, the electrolysis of water forms hydrogen. Both of these factors affect hexavalent chromium and other heavy metals in the wastewater.

Figure 1 compares the rate of hexavalent chromium reduction in the electromagnetic nano-mill compared with a conventional stirrer.

Fig. 1. Wastewater Treatment Unit. The rate of hexavalent chromium reduction: 1, 2, 3 – in a stirrer with consumption of the reducing agent FeSO4 of 50%, 80% and 100% of the stoichiometric amount; 4, 5 – in the AVS with consumption of reducing agent FeSO4 of 10% and 30% of the stoichiometric amount.

Analyzing the data makes it clear that the electromagnetic nano-mill achieves a full recovery of hexavalent chromium with 10% of ferrous sulphate. The process takes almost no time and lasts a fraction of a second.

Figure 2 shows a complete process line with the AVS for wastewater treatment.

Fig. 2. Wastewater Treatment Unit. Flow chart for wastewater treatment from chromium on the AVS: 1 –mixing tank, 2 – pump, 3 – reducing agent tank 4 – alkali dispenser, 5 – acid dispenser, 6 – electromagnetic nano-mill (AVS).

The principle of operation is as follows. Wastewater with hexavalent chromium goes into the mixing tank, where acid concentration is equalized and more acid is added. After that the wastewater goes into the AVS, simultaneously mixed with ferrous sulphate or sodium bisulfate. The flow meter adjusts the flow rate.

After chromium recovery the waste water flows into the second AVS with lime milk, forming chromium hydroxide and other heavy metal salts. The acidity level is controlled by a pH meter, which is placed over the device.

If the residual concentration of hexavalent chromium exceeds the desired value, it is necessary to adjust reducing agent consumption.



要查看或添加评论,请登录

Anna Morynets的更多文章

  • CEMENT GRINDING IN VORTEX LAYER DEVICES

    CEMENT GRINDING IN VORTEX LAYER DEVICES

    In this article, we will discuss how cement grinding, cement activation, microcement production, and dry mortar…

  • Hydrogen gas concentrations

    Hydrogen gas concentrations

    A hydrogen sensor is a device that can detect the presence of hydrogen gas. Since hydrogen occurs naturally in very…

    2 条评论
  • TRANSFORMER DIELECTRIC FLUID ANALYSIS

    TRANSFORMER DIELECTRIC FLUID ANALYSIS

    Dissolved gas analysis Main gases detected: H2 (hydrogen), O2 (oxygen), N2 (nitrogen), CH4 (methane), CO (carbon…

    1 条评论
  • Over 30,000 mines are leaking toxic waste into American waterways

    Over 30,000 mines are leaking toxic waste into American waterways

    GlobeCore company has it's own the most important goal - to save our planet. We develop our products and always…

    1 条评论
  • TRANSFORMER OIL POLISHING

    TRANSFORMER OIL POLISHING

    In this article we will look at “oil polishing”: the meaning of the term, when this process is needed and how it is…

    1 条评论
  • PRODUCTION OF BLENDED FUELS

    PRODUCTION OF BLENDED FUELS

    Although blending fuel issue is relatively young, it increasingly attracts attention of both young and experienced…

  • Capture, neutralization and utilization of industrial gas emissions. "Greenhouse effect"

    Capture, neutralization and utilization of industrial gas emissions. "Greenhouse effect"

    An attack on the life and health of people, on the flora and fauna of the Earth - it is difficult to find words to…

  • REMOVAL OF PHOSPHATES FROM WASTE WATER

    REMOVAL OF PHOSPHATES FROM WASTE WATER

    Chemical waste water, containing phosphates, is environmentally hazardous. Most facilities use one of the two phosphate…

    1 条评论
  • Sewage facilities, Drinking water

    Sewage facilities, Drinking water

    The municipalities are facing the problem of drinking water for a long time. But it has not been solved and there are…

    1 条评论
  • TRANSFORMER SAFETY SYSTEM TSS (online transformer service)

    TRANSFORMER SAFETY SYSTEM TSS (online transformer service)

    Purification and regeneration of electrical insulating oils are an important integral part of the measures aimed at…