VISION LEADS TO GREAT: Huawei Launches Next-Generation Data Center Facility and PowerPOD 3.0
On May 26, 2022, We launched our brand new Power Module 3.0 solution and revealed our vision for the next generation of green data centers. Thanks to our global customers and partners who joined the unveiling.
Technical experts and industry authorities have reached a consensus on the four characteristics of next-generation data center facilities after extensive and in-depth discussions, that is, Sustainable, Simplified, Autonomous Driving, and Reliable.
Sustainable: Next-generation data center facilities will be fully green and energy-efficient while maximizing the recycling of all data center materials. In this way, the overall data center ecosystem will be eco-friendly and environmentally sustainable. Sustainable data centers can be achieved by utilizing green resources - electricity, land, and water - and maximizing the recycling of used materials throughout the life cycle. In addition to the extensively-used Power Usage Effectiveness (PUE), other indicators, including Carbon Usage Effectiveness (CUE), Water Usage Effectiveness (WUE), and Grid Usage Effectiveness (GUE), will also be used to measure data center sustainability.
Simplified: Simplified architecture, power supply, and cooling embody the evolution of the data center facility.
Simplified architecture brings innovative forms of buildings and equipment rooms. If the prefabricated modular construction mode is used to construct a 1000-rack data center, the construction period can be reduced from more than 18 months to 6–9 months.
Simplified power supply reshapes components and links. It shortens the delivery period from 2 months to 2 weeks. Simplified cooling maximizes heat exchange efficiency by changing multiple heat exchanges to one heat exchange, and shortening the cooling link.
Autonomous Driving: O&M automation, energy efficiency optimization, and operation autonomy reshape the management of data centers’ operation and maintenance. O&M automation enables engineers to complete the inspection of 2000 racks in 5 minutes remotely. The energy efficiency optimization means an optimal cooling strategy can be delivered via 1.4 million original combinations within 1 minute, achieving smart cooling. Operation autonomy maximizes the value of resources.
Reliable: Proactive security and secure architecture ensure high quality and sustainable development of data centers. Proactive security means using big data and AI technologies to implement predictive maintenance from components to data centers, based on the visibility and perception of all domains in the data centers. Automatic fault response means it will take only 1 minute to spot a fault, 3 minutes to analyze, and 5 minutes to recover. Secure architecture means security will be ensured at various levels, such as components, devices, and systems. At the system level, the E2E visualizable, manageable, and controllable platform enables the system availability to reach 99.999%.
While others try to predict the future we create it.
领英推荐
At the event, Fei Zhenfu, CTO of Huawei Data Center Facility Team, released a new generation of the power supply system, known as PowerPOD 3.0. The system reduces the footprint by 40%, cuts the energy consumption by 70%, shortens the delivery period from 2 months to 2 weeks, and lowers the SLA fault rate by 38%.
Footprint saving: 40% smaller footprint
By using an innovative converged architecture and the industry's ultra-high-density UPS5000-H, the power density per cabinet is increased and the space layout of the power supply system is optimized. The number of cabinets is reduced from 22 to 11, resulting in a significant footprint decrease. In a 12 MW data center, for example, the footprint saved by the PowerPOD 3.0 solution allows for deploying more than 170 additional racks compared with a traditional power supply solution.
Power saving: 70% lower consumption
The link efficiency of a traditional power supply solution is generally lower than 94.5%. In contrast, PowerPOD 3.0 raises the efficiency up to 97.8% while shortening the link length. In addition, the UPS5000-H delivers an efficiency of 99.1% in S-ECO mode, effectively reducing power consumption. Using the PowerPOD 3.0 in a 12 MW data center will save nearly 300,000 U.S. dollars each year.
Time saving: 75% shorter delivery
A traditional power supply solution requires about 35 copper bars and 180 cables to be connected onsite, resulting in high-quality risks and a delivery period of 2 months. The PowerPOD 3.0 uses tray-alike prefabricated busbars for internal connections. With prefabrication and commissioning completed in the factory, onsite construction can be completed only in 2 weeks, accelerating service rollout for customers.
Worry free: 40% lower fault rate in SLA
Based on the concept of "autonomous driving" and AI technologies, the PowerPOD 3.0 is armed with iPower intelligent feature, which provides two-layer reliable designs for end-to-end visibility as well as AI temperature prediction, life prediction of key components, and intelligent setting. Automatic and predictive O&M becomes possible.
VISION LEADS TO GREAT. We embrace the future of smart and sustainable data centers by building simplified, efficient, reliable, and greener power supply systems for data centers. We create new value for customers.?