The veins on this steel vertical inline pump for a cooling tower at a refinery had severe abrasion wear because of the 30 years of service it provided

Vertical Inline Pump Repair for Cooling Tower

The veins on this steel vertical inline pump for a cooling tower at a refinery had severe abrasion wear because of the 30 years of service it provided.? The client wanted to see how the Resimac products could perform against the competition, and it came out with an exceptional review.

SUBSTRATE

Steel

PRODUCTS USED

SOLUTION

As you can see, the vein was 50% gone so the vein needed to be rebuilt with Resimac 201 Ceramic Repair Paste and Resimac 808 Reinforcement Mesh Tape.

After we rebuilt that piece, there were 6 other pieces of the pump that we coated with two coats of Resimetal 202 Ceramic Repair Fluid on the inside. This created a smoother surface for pump efficiency and provided abrasion resistance.

All the external pieces of the pump were coated with Resichem 501 CRSG in two colors.

With the 2-color system, when the pump goes back in service the client will be able to tell if the pump needs recoating because the gray layer will wear out showing the blue layer.?If the client chooses this method of prevention, they will not need to rebuild the structure and will only need to put the top color coat on in the future.

We coated with two coats of
With the 2-color system, when the pump goes back in service the client will be able to tell if the pump needs recoating because the gray layer will wear out showing the blue layer.

Partner with us to repair, protect, and upgrade your systems with our composite repair and protective coating solutions. | https://www.usigroups.com/

Doug Klingensmith