Understanding Arc Flash Containment and Risk Level
Mark Shorrock
Helping Businesses Achieve Growth Through Strategic Sales, Marketing, and Operations Optimisation | Business Development Specialist | Trainer & Consultant
Arc flash events pose serious risks to personnel and equipment in electrical systems.
What is Arc Flash Containment?
Arc flash containment refers to the measures taken to mitigate the impact of an arc flash event, minimizing its extent and preventing catastrophic damage. Containment systems typically include barriers, enclosures, and personal protective equipment (PPE) to shield workers and equipment from the effects of an arc flash.
Why is Arc Flash Containment Important?
Arc Flash Risk Level Assessment
Containment Strategies:
By understanding arc flash containment measures and conducting comprehensive risk assessments, organizations can effectively mitigate the risks associated with arc flash events, ensuring the safety of personnel and the integrity of electrical systems.
Feel free to reach out if you have more questions or need further details on this topic!
#ArcFlash #SafetyFirst #ElectricalSafety #RiskManagement
Manager Health, Safety, Security & Environment, Ecomar Energy Solutions, ECOMAR Refinery, Fujairah, UAE.
1 个月It's an interesting topic, thanks for sharing. Arc flash study is to determine the incident energy available at specific device that an operator would be exposed to, while interacting with electrical equipment at facility. The result of Arc flash study will categorize the Hazard at specific equipment based on the incident energy, as well as identify the Arc flash protection boundary (the closest approach allowed before PPE must be worn). And inside the Arc flash protection boundaries a worker must be wearing proper clothing/ PPE. The PPE, main objective to wear is to restrict, or stop the burns of the body resulting from an arc flash event, to a survival level. The Arc flash Hazard study is done, in association with short circuit & protection device coordination study,as per IEEE Stnd 60909 and IEEE Stnd 242, respectively. Based on study findings, selection of PPE, electrical equipment of switchgear, substation shall be selected, rated, and warning levels A, B, shall be displayed "Arc Flash and Shock Hazard Present and Appreciate PPE are Required".
Helping Businesses Achieve Growth Through Strategic Sales, Marketing, and Operations Optimisation | Business Development Specialist | Trainer & Consultant
8 个月Let me know if you have a topic you'd like covered
Helping Businesses Achieve Growth Through Strategic Sales, Marketing, and Operations Optimisation | Business Development Specialist | Trainer & Consultant
8 个月Thanks to Nico Strydom for suggesting that I cover this topic with a post, which I've also published as an article.
Thanks for another informative article Mark Shorrock