Typical hidden heat transfer issues in a heat exchanger

In the field of heat transfer and heat exchangers, there are various complexities that are not widely known or understood in routine day-to-day work. These can include issues related to fluid flow characteristics (turbulent vs. laminar), Reynolds number (Re), and two-phase flow (such as boiling or condensation). Temperature cross, which refers to situations where the hot and cold fluid temperatures at the outlet differ from the desired values, can also be a problematic issue in heat exchangers. For the general public or those without direct involvement in such fields, these concepts might indeed be hidden or not well-known.

Details

Three typical issues

Reynolds number of the flow regime prediction

The transition from laminar to turbulent flow can indeed introduce some unpredictability in heat transfer. Reynolds Number (Re) is a dimensionless quantity used to characterize the flow regime, and the critical value for the transition from laminar to turbulent flow is typically around 2,100 to 4,000.

In laminar flow, the fluid moves in smooth layers, and heat transfer can be accurately predicted using simplified equations, such as the convection equation. However, once the flow becomes turbulent, heat transfer becomes more complex due to the formation of eddies and irregular flow patterns. Turbulent flow creates enhanced mixing, and therefore, heat transfer rates can increase significantly.

The transition from laminar to turbulent flow can be challenging to predict because it depends on various factors, such as flow velocity, fluid properties, and geometrical characteristics of the system. Even a slight change in these parameters can cause the flow to transition from laminar to turbulent or vice versa.

Temperature cross

The term "temperature cross" refers to the phenomenon where the temperature of the hot fluid becomes lower than the temperature of the cold fluid in a heat exchanger or similar systems. It is typically caused by factors such as phase change or other heat transfer mechanisms that result in adiabatic cooling of the hot fluid. When the hot fluid undergoes a phase change, such as from liquid to vapor, it consumes internal energy and experiences a temperature drop. This narrowing temperature gradient, or delta T (ΔT), between the hot and cold fluid, can lead to a temperature cross and potentially impact the overall heat transfer performance of the system.

Phase transition

In a heat exchanger, a phase transition can affect the heat transfer coefficients operating within the system. When a phase change occurs, such as the vaporization of a liquid, the heat transfer process undergoes a significant change.

During the phase transition, there can be a sharp increase in heat transfer coefficient due to the latent heat released or absorbed during the process. This sudden change in heat transfer coefficient is often significant and can enhance the overall heat transfer rate within the heat exchanger.

However, it is important to note that the phase transition and the associated change in heat transfer coefficient do not remain hidden. The effects of phase change, especially in the form of pressure drops or changes in system behavior, are usually apparent during the operation of the heat exchanger. These changes can typically be detected through pressure measurements, temperature differences, or other performance indicators of the heat exchanger.

The downside of two-phase flow

While the heat transfer coefficient does increase during phase change, it should be noted that phase change in a heat exchanger can lead to erosion issues. When a substance changes phase, there can be significant pressure and velocity changes, which can cause erosion or damage to the heat exchanger surfaces.

Mitigation of phase transition

Maintaining proper temperature distribution across a heat exchanger is essential to avoid two-phase flow or phase change in the system. Uneven temperature distribution can lead to localized areas of significantly higher or lower temperatures, which in turn can cause phase change or two-phase flow to occur. In a heat exchanger, the fluid flowing through the tubes or channels should have a uniform temperature distribution to promote efficient heat transfer. This can be achieved by proper design considerations such as adequate flow distribution, appropriate sizing of tubes or channels, and optimizing the heat transfer surface area. If the temperature distribution is not properly managed, certain areas of the heat exchanger may experience higher temperatures that can cause the working fluid to reach its boiling or saturation point, leading to phase change. Alternatively, if there are colder zones, condensation may occur. Both scenarios can lead to two-phase flow, reduced heat transfer efficiency, and potential equipment issues like erosion or damage.

?