In Tube Condensation: Changing the Pressure Drop into a Temperature Difference for a Wire-on-Tube Heat Exchanger

In Tube Condensation: Changing the Pressure Drop into a Temperature Difference for a Wire-on-Tube Heat Exchanger

This is from the Editorial Office of Journal?FDMP-Fluid Dynamics & Materials Processing. FDMP is currently indexed by all major databases, including ESCI, Scopus, EI,Google Scholar, etc...

We are pleased to present this paper "In Tube Condensation: Changing the Pressure Drop into a Temperature Difference for a Wire-on-Tube Heat Exchanger" from our special issue "Recent advancements in thermal fluid flow applications"?.We sincerely invite you to read full paper?here.

图片无替代文字

A theoretical study based on the Penalty factor (PF) method by Cavallini et al. is conducted to show that the pressure drop occurring in a wire-on-tube heat exchanger can be converted into a temperature difference for two types of refrigerants R-134a and R-600a typically used for charging refrigerators and freezers.

The following conditions are considered: stratified or stratified-wavy flow condensation occurring inside the smooth tube of a wire-on-tube condenser with diameter 3.25, 4.83, and 6.299 mm, condensation temperatures 35°C, 45°C, and 54.4°C and cover refrigerant mass flow rate spanning the interval from 1 to 7 kg/hr.

The results show that the PF variation is not linear with vapor quality and attains a maximum when the vapor quality is 0.2 and 0.18 for the R-134a and R-600a refrigerants, respectively. The PF increases with the refrigerant mass flow rate if the inner diameter and saturation temperature constant, and it decreases on increasing the inner diameter to 6.299 mm for constant refrigerant mass flow rate and saturation temperature. The PF for R-600a is higher than that for R-134a due to the lower saturation pressure in the first case. Furthermore, a stratified flow produces higher PF in comparison to the annular flow due to the effect of the surface tension.

图片无替代文字

The study theoretically succeeds in determining the effect of the mass flow, inner tube diameter, and saturation temperature on the PF.The PF method can be used to make comparisons with the entropy generations method during the condensation when the important points of the type of flow pattern, inner tube diameter, saturation temperature, and mass flow rate are taken into consideration.

I would like to invite you to read these articles and share your thoughts with us.

Thank you for your time and attention.

Sincerely,

FDMP Editorial

Contact Us:

Whatsapp: +1 702 927 2320

Email: [email protected]

Office Hours: 9:00-17:00 (UTC -8:00)

要查看或添加评论,请登录

Tech Science Press的更多文章

社区洞察

其他会员也浏览了