Thermal Bridging in SAP 10.0
A typical heat flux diagram showing increased heat loss through the lower courses of the inner leaf of a cavity masonry wall

Thermal Bridging in SAP 10.0

In July, SAP 10.0 was formally published, incorporating a few important changes. Arguably one of the more significant updates is to the way thermal bridging is treated (specified in Appendix K). This will affect both the carbon calculations, and the Fabric Energy Efficiency (FEEs) criterion. This blog will consider the implications of the changes to Appendix K.

The key changes to Appendix K are

  1. Adjustments to some of the default psi-values
  2. A significant increase in the default Y-value
  3. The removal of the Accredited Construction Details

Also, a minor point is that a new junction, R10 has been added, which is “all other roof or room-in-roof junctions”, to cover the multitude of exciting features invented by architects that cannot be understood by mere mortals. The notional building’s psi-values remain the same.

The following chart shows the changes to the psi-values.

Many of the worst-affected psi-values are those involving party walls, so will penalise blocks of flats for example. Roof windows and balconies are also subject to significant uplifts, and most other junctions within roofs, which were only introduced in 2012, and don’t have accredited detail values are also affected.

What does this mean for your project?

We have analysed two case studies based on real projects we have been involved with. Firstly, a typical cavity-masonry house by a mid-size house building company, and secondly a flat within a typical mid-rise building consisting of a concrete frame with SFS infill.

The first graph shows the relative contributions of the different junctions, expressed in terms of the Y-value. The total height of each bar represents the Y-value for each scenario, so it can be seen that under the 2012 default values, the Y-value is 0.19 W/m2.K, which is actually worse (higher) than the default Y-value for 2012, meaning that if the measurements of the junctions were taken, but no improved details were selected, the building would actually be penalised. It can also be seen however, that simply opting for the accredited details gives a significant improvement, reducing the Y-value to about 0.08 W/m2.K. This explains the popularity, and why they have been arguably abused.

Also shown is the disaggregated Y-value for the Notional building, which provides a useful point of reference and something designers may wish to target. It’s interesting that in this case, although the value is made up differently, the overall Y-value (i.e. the contribution of thermal bridging to the heat loss) is almost the same as for our fully-assessed design at 0.035 W/m2K.

For this project, the total impact of thermal bridging would actually be less if default values were taken in a SAP 10.0 assessment, because some of the longer junctions are those whose default psi-value is actually reduced in SAP 10.0.

As might be expected, the best results can be had by obtaining psi-values from libraries such as Advanced Details or by a full thermal bridging assessment. In this case, we calculated the Y-value to be 0.036 W/m2.K. This is without any major design changes or specification of special materials to reduce heat flux through junctions; enhancements to the design could reduce this further.

It’s also worth pointing out what the Y-value means, and to set the impact in context. We are not big fans of the Y-value; although it neatly represents the overall thermal bridging impact, it can hide a multitude of sins and can be confusing. The Y-value can be compared directly with the U-values because it takes the same units. If the average U-value for this house was, say 0.18 W/m2.K, it would mean that the effect of thermal bridging increases this to 0.215 W/m2.K. This is not at all insignificant, and this is for a relatively good example. If the new default Y-value was taken, it would almost double the heat losses! The following graph shows the total heat losses from the same building under different thermal bridging situations.

The height of the bars represents the heat loss parameter, which is a metric not usually discussed in relation to SAP, but it is convenient for this illustration. It is roughly analogous to the Fabric Energy Efficiency but does not consider the heat gains.

When SAP 10.0 comes into force (currently unannounced, but we would anticipate it to be late 2019 or 2020), the approved details route will no longer be available. Given that it is already often impossible to pass the FEEs criteria on default values, it will be essential to obtain proper thermal bridge assessments.

Another very important advantage of a full thermal bridging assessment is that the risk of internal surface mould or condensation can be checked. The additional heat flux through the thermal bridge can reduce internal surface temperatures, which increases relative humidity. If the effect is severe enough, conditions might be conducive to mould growth or even the formation of condensation. Approved Documents L and C provide criteria for assessment of this risk, so as well as being a practical concern it is also a compliance issue.

In our next blog we will present another example where assessing thermal bridging creates some counter-intuitive results.



Brandon Wipperfurth

Pushing the boundaries towards zero-carbon in construction

6 年

This is well written. I applaud SAP 10 for retiring the ACD's as Scotland already has.? Some of the values were grossly inappropriate and their removal should only create more awareness around thermal bridging as an issue in the wider industry.??

Jason Hewins

New Build Dwellings Manager at Elmhurst Energy Systems Limited

6 年

Very interesting reading. The key question is will the next version of Part L carry on with the FEE or move to something different? It's difficult to quantify what affect SAP 10 will have on design until we know the next changes to regulations as some designs may be more penalised than others.

要查看或添加评论,请登录

Toby Cambray的更多文章

  • Treading Lightly on the Grid

    Treading Lightly on the Grid

    Many energy wonks in the industry like me are currently contemplating The Future Homes Standard Consultation, and…

    9 条评论
  • What space travel can teach us about insulation on earth

    What space travel can teach us about insulation on earth

    In case you have been living under a lunar rock, this summer marked is the 50th Anniversary of the moon landings. As an…

    1 条评论
  • Salt: It's on your chips and in your building

    Salt: It's on your chips and in your building

    When I was growing up, my Dad (a science teacher) occasionally asked us to ‘pass the Sodium Chloride’ at the dinner…

    2 条评论
  • Think you understand how other people think?

    Think you understand how other people think?

    Think again. You’re not even close, and probably never will be.

    5 条评论
  • How to solve the low-carbon heating crisis

    How to solve the low-carbon heating crisis

    I was asked the following question in a comment replying to my last article looking at the carbon emissions factor of…

    15 条评论
  • Electricity Carbon Factors in SAP 10

    Electricity Carbon Factors in SAP 10

    A major change in SAP 10 is the introduction of a lower carbon factor for grid electricity that will lower the…

    14 条评论
  • So you think you want MVHR...

    So you think you want MVHR...

    Great! Here are some important factors to consider before taking the plunge. (originally posted on www.

    1 条评论
  • Thermal Bridging in SAP 10.0 - Part Deux

    Thermal Bridging in SAP 10.0 - Part Deux

    Last month, I explored the changes to thermal bridging calculations that will be introduced in SAP 10.0 and set these…

    4 条评论
  • SMART STRATEGIES FOR STEEL-FRAMED BARN CONVERSIONS

    SMART STRATEGIES FOR STEEL-FRAMED BARN CONVERSIONS

    In the late 90s and early 2000s, anyone who was anyone was converting a barn to a home. Modern farms with more acreage…

  • Is your modelling Good Enough?

    Is your modelling Good Enough?

    Why bother with energy modelling of buildings? It’s a simple question and on one level some simple answers, but I think…

    5 条评论

社区洞察

其他会员也浏览了