Testing an EV Charging Station / E-charging Station
Redmark Industry Sdn Bhd
One stop centre for supplying testing and measuring equipment, maintenance, calibration and automation
Testing an EV Charging Station / E-charging Station
The quite natural everyday handling of electric current
An EV charging station is usually connected to the three-phase alternating current with 400 volts in order to be able to generate high charging power. So that the installation or operation of the charging stations did not lead to endangering people, overloading the grid or to the failure of the power-operated equipment and systems, the Charging Station Ordinance was passed in 2016 for publicly accessible charging points in addition to the requirements that apply to every EV charging station. It lays down the minimum technical requirements for safety and also for general accessibility.
Initial and repeat tests
Every EV charging station belongs to the electrical installations on which the initial tests according to DIN VDE 0100-0600 (IEC 60364-6) and repeat tests according to DIN VDE 0105-0100/A1 (IEC 60364-6, Clause 6.5) and VDE 0122-1 (IEC 61851-1) must be carried out by the qualified electricians
The first test steps include the visual inspection
领英推荐
Adapter for simulating charging processes and faults for the measurements
When testing the e-charging station, all the charging states that actually occur should be tested reliably and with the repeatable accuracy without a vehicle. Without the vehicle being connected, however, the charging station must not emit any voltage. Special test adapters can not only simulate the various vehicles charging levels and charging cables. The EVSE adapters also enable convenient measurement of the voltage and signal cables with conventional installation testers simply via the plug connection of the EV charging station.
CP traffic jams – vehicle charge levelsResistance CP-PEA???No vehicle connected open B???Vehicle connected 2700 OhmC???Vehicle ready for charging (without ventilation) 880 OhmD???Vehicle ready for charging (ventilation required)240 OhmE???CP errorCP-PE short circuit
PP status - charging cable typeResistance PP-PENC – no cable connected?open13 amps1500 ohms20 amps????????680 ohms32 Amps???????220 Ohms63 Amps100 Ohms
As a rule, the EVSE adapters are additionally equipped with a function to simulate an earth fault