The Standpipe Kit
High-rise building fires can be the most challenging and dangerous operation for a firefighter. An important element for success in high-rise fire incidents is "the standpipe kit". These kits include all the essential tools a crew may need to conduct standpipe operations. In the article titled, "The Standpipe Kit", published in WNYF (2nd/2015), describes the components that make up a functional kit. This article serves as a useful guide for creating or updating your department's own kit.
The basic standpipe kit should include:
- Door chocks and wedges (assorted)
- Spanner wrenches (2)
- Off-set pipe wrench (18" minimum) - to remove caps or operate stripped control valves
- Control valve wheels - various sizes, as needed for the response area
- Wire brush
- Pressure gauge or standpipe flowmeter
- Nozzle (spare)
- Adapters and couplings (various)
- Gate valve
This list presents basic items that should be included in every kit. Pre-fire planning for your response area must be conducted. Based on the pre-fire plans other adapters, thread types, sizes, or items may be needed and should be added to the kit.