For those familiar with measurements of ESD (electrostatic discharge) properties of infrastructures, the floor measurement probe should be a common item.
?
Other uses include the measurement of electrical conductivity of work surfaces (tables, cabinet shelves, machinery etc.), but also chairs and solid planar materials (part of material science).The construction and appearance of the probe has everything to do with what type of measurement is performed with it.
As mentioned before: The probe is used to measure the electrical conductivity of an object. However, what is not said is that this conductivity is dependent on the applied test voltage and the applied pressure.
These parameters are important as they determine the outcome of the measurement.
Even so much, that the contribution of the probe should be regarded as more critical, than the high impedance meter with which the measurement is performed. And yet, when a impedance measurement kit is offered for calibration, it is observed at many calibration companies, that they focus on the impedance meter and do not calibrate the probes.
Calibration of electrical (floor) resistance probes:
The parameters of the floor probe are described in various standards: IEC 61340-4-1 (ANSI STM7.1) , IEC61340-2-3 (ANSI STM4.1). Yes there are more standards that described these probes, but they basically come down to the same descriptive range.
"It must be noted that all parameters of the probe should apply to the finished product, not to individual parts of the probe".
Should you offer floor resistance probes or any other ESD related resistance probe (like a 2-point probe or a concentric ring probe) for calibration, then these parameters should all be checked and reported upon in the calibration report.
?
领英推荐
Other aspects worth noting!
There are several floor resistance probe configurations available on the market. Some are fitted with carbon filled conductive pads, others with conductive pads containing silver particles. Both can do an equally good job, however, it has been observed that the ones (first generation) using a silver particle filled conductive pad, are more susceptible to wear/ degradation and react with solvents like isopropanol or ethanol.
As a result, due to damage or degradation, these pads will become concave or convex (depending on where the wear/ degradation occurs). (See picture below)
Not all of this unintended “reshaping” of the conductive rubber pad surface can be observed with the naked eye. It can be measured though, using a device that measures the electrical conductivity over a set of predefined points across the pad area. The resulting resistance should lie in between a tightly fixed range. If this is not the case, then your probe is not flat and smooth anymore.The effect of (unknowingly) using convex or concave conductive pads, is that less contact with the specimen occurs, which results in higher resistance values. This may lead to rejection of the floor, or any other materials under test using these probes.
Have all probes a certification or validation?
While certifications can provide valuable assurances regarding the effectiveness of ESD probes, unfortunately not all manufactors/suppliers of probes have separate ESD certifications due to different factors. So ask for it!
"So our advice to you is: let your probes also checked yearly and certificated to avoid problems or wrong measurement values".
Unlock your potential with Eurostat Group! We provide expert advice and tailored solutions for all types of measurement devices to perfectly meet your needs.
Episode 1 : The “secret” aspects of good ESD measurement probes!
Eurostat Group - Pim Dik (co-auteur) Total Esd Solutions - Tim Maas (co-auteur)
?
Semiconductor Quality Engineer | Esd Specialist | Cleanroom Specialist | Internal Auditor
2 天前A Importancia do Uso de Luvas ESD Revestidas de Poliuretano e Luvas de Tecido Antiestático no Processo Industrial https://www.dhirubhai.net/pulse/import%C3%A2ncia-do-uso-de-luvas-esd-revestidas-e-tecido-elias-manfrin-ha26f?utm_source=share&utm_medium=member_android&utm_campaign=share_via
Técnico | Process Maintenance | Samsung Electronics | CFT Ativo
3 个月Willian Kishida