Saving costs and improving effluent by knowing what is happening in your bioreactor - Part I
This is Part I of a series of three articles describing a globally unique advanced modelling project in the water sector, explained in a practical and easy way. Yes, quite extensive, but it reads fast. Although focused on wastewater here, ‘drinking water people’ can also benefit from reading it. By the way, if you don’t like reading (or you can’t wait), just scroll down and watch the explanatory action movie immediately. This part focuses on measurements and unprecedented model validation using a construction crane. More details of such projects are made available in the AM-TEAM newsletter. (PS: PART II is also out)
1. The full-scale plant and the problem to solve
The Eindhoven water resource recovery facility (WRRF) is a 750,000pe conventional activated sludge plant, operated by Waterboard De Dommel (Netherlands). While the plant operators want to lower effluent nitrate, low levels are hard to get, especially during cold weather. Finding optimal performance of the existing bioreactor is done before a plant upgrade with an advanced denitrification step to see if upgrade is needed. Both our previous modelling work and practical observations have shown that elevated oxygen levels near the intake of the anoxic tank may hinder denitrification in the bioreactor, so this is where we pointed our arrows on.
Figure 1: The Eindhoven WWTP. Measurement locations in one of three identical bioreactors. Red circles show the reach of the construction crane. Orange dots: oxygen measurements, red dots: velocity measurements.
2. The modelling objective
- Offer solutions to lower effluent nitrate significantly, whereby operational measures are preferred over design modifications
- Save costs (not a primary objective but nice to have)
- Detect other optimisation opportunities along the way
3. The strategy - what is the value of modelling?
As conventional trial-and-error testing would be risky, laborious, time consuming and would provide limited testing freedom and knowledge extension, Waterboard De Dommel decided to adopt a structural advanced modelling approach. Our proprietary CFD-biokinetic model developed throughout the years was ready to use, so we could start fast. First, we wanted to extensively validate the model to remove any remaining doubt about model validity. Actually, we wanted to demonstrate the validity of an advanced model like no one did before. And this is where this article is about.
Questions for the validation:
- Do we observe in reality the same oxygen gradients as predicted by CFD?
- Do the measured gradients correspond to the simulated gradients?
- Is the model accurately predicting the flow velocity?
4. Why the heck did we hire a construction crane?
I will answer your question immediately: no, you don’t always need a crane for model validation. But if you have it, you can collect a rather spectacular data set. The crane allowed us to perform extensive oxygen profiling, leading to a 3D image of oxygen levels along the depth, width and length of the large bioreactor. This is an ideal dataset to compare to the 3-dimensional CFD results. We measured a whole day and collected oxygen data at 99 locations in the bioreactor. If we add the sensor of the bioreactor, we reach 100 (hurray!). 3 LDO sensors were attached to the chain of the crane, leaving several meters of spacing. A 700 kg concrete block had to keep the chain vertical, and it luckily did without detaching ??.
Figure 2: Submerging the oxygen sensors with the crane along one cross section
Besides oxygen, we collected velocity data at 8 locations, along the depth of the reactor. Also these local velocities of flow were then compared to model outcomes as an extra validation variable adds a lot of information. To challenge the model and collect extra information, the plant operator doubled the aeration rate halfway the measurement campaign.
5. Why is the model so accurate?
In many cases we have seen people applying rather simple CFD models to model activated sludge systems. For example, the density of clean water is used and other dangerous assumptions are made (eg. how the aeration system is modelled). Based on our experience, these simple approaches have very limited accuracy and hence, value, while also these cases produce nice colourful drawings. Our activated sludge model was developed and improved throughout the years and contains proprietary equations. Further, biokinetics (e.g. ASM1) are integrated, so the model is also able to calculate sludge, nutrient and carbon conversion rates and concentrations in 3D. Flows and concentrations can be simulated within a couple of hours, making testing of many different scenarios possible. AM-TEAM co-founder Dr. Usman Rehman developed this model during his PhD at BIOMATH, UGent under supervision of prof. Ingmar Nopens and in collaboration with Waterboard De Dommel.
6. Results
6.1. Velocity
The next graphs show velocity profiles across the depth of the reactor. These recordings relate to a cross section: the blue data points were recorded near the inner reactor wall, the brown ones close to the outer wall. Using the simple, and conventional, CFD modelling approach, we typically obtain an accuracy as shown left.
Figure 3: Velocity data compared to simulated data using the 'standard' approach (left) and AM-TEAM's in-house approach (right)
After a major improvement, the fit in the middle was obtained. After further improvement of the model with a second major feature, we ended with the fits shown on the right, and in detail further. We were happy to see that the model accurately describes the data trends, which means the main mechanisms were taken into account. Adding more resolution to the CFD model clearly increased model accuracy and value significantly.
Figure 4: More detailed comparison of velocity data and simulated data using AM-TEAM's in-house approach
6.2. Dissolved oxygen
The figures below show comparisons between dissolved oxygen data and simulated air distribution at 4 locations. The biokinetic model was not yet activated at this stage of the project, so there is no simulated oxygen data yet. However, we can assume (and we have seen in past) that DO levels and air are correlated and that more DO can be found where more bubbles are.
Figure 5: comparison of air distribution (gas holdup) and measured DO concentrations at 4 locations in the bioreactor (A and B are in the aerated zone)
Measured oxygen gradients looked as we expected based on the CFD outcomes.
Conclusions regarding DO:
- Large DO gradients exist, even, and especially in the aerated zone, which often is regarded as a completely mixed zone. Differences of 96% along the measured depth were found
- Higher DO levels were measured at the expected locations (near the surface and inner wall)
Although many readers will know this, it is worth repeating that water and air are no best friends, resulting in typical hydrodynamic segregation of the phases. Bubbles like being together, probably reducing the overall area available for mass transfer.
7. General conclusions
- Never before, the accuracy of CFD modelling for water applications was assessed and demonstrated like this
- Producing nice colorful drawings is easy. Producing accurate ones requires advanced expertise
- The plant is currently being changed based on model outcomes (next articles)
- Completely mixed reactors, or even zones, do not exist. We have to live with that and more importantly, account for that. Not neglecting mixing will save the water sector a lot of money and time in future.
These results were partially presented at Weftec 2017 (Chicago), will be presented at the IWA Large WWTP conference in Chongqing, China, and will also be published scientifically.
Want to continuously stay updated on such projects? Opt in for our newsletter at AM-TEAM.com, follow us at LinkedIn and watch our movies at our youtube channel AM-TV.
Next articles (+ videos) to come
- Part II (just published!): model-based plant optimisation
- Part III (last article): impact of the modelling study in terms of money and plant performance
Special thanks to
- Waterboard De Dommel: Tony Flameling, Peter van Horne, Han van Happen, Victor Claessen, Stefan Weijers, Peter van Dijk (overall help and support)
- Ghent University – BIOMATH: Giacomo Bellandi, Tinne De Boeck, Cha?m De Mulder, Ingmar Nopens (scientific discussions and measurement campaign)
- Kinnear Process Solutions: Dave Kinnear (equipment for velocity measurements)
- Waassolar sustainable energy: Chris Poppe (spectacular air images with drone)
?CEO and co-founder at AM-Team?
6 年Everyone! Finally, here is part II. Enjoy reading it. Curious about your comments. Wim?https://www.dhirubhai.net/pulse/saving-costs-improving-effluent-quality-knowing-what-happening-usman/
Sales Manager DACH-Area Nijhuis Water Technology
7 年Really interesting, what happens in the different sections!
?CEO and co-founder at AM-Team?
7 年Great to see so many people are enthousiastic about it. More coming soon!
Engineering Consulting Services to Industries on Waste Water Treatment, Water Recycling & ZLD , Biogas from waste
7 年Very Good Excercise and study
Senior Scientific Assistant at Surat Municipal Corporation
7 年Absolutely brilliant and innovative