PK-002 Absorbent Glass Mat (AGM)

PK-002 Absorbent Glass Mat (AGM)

AGM technology became popular in the early 1980s as a sealed lead acid battery for military aircraft, vehicles and UPS to reduce weight and improve reliability. The sulfuric acid is absorbed by a very fine fiberglass mat, making the battery spill-proof. This enables shipment without hazardous material restrictions. The plates can be made flat to resemble a standard flooded lead acid pack in a rectangular case; they can also be wound into a cylindrical cell.

AGM has very low internal resistance, is capable to deliver high currents on demand and offers a relatively long service life, even when deep cycled. AGM is maintenance free, provides good electrical reliability and is lighter than the flooded lead acid type. While regular lead acid batteries need a topping charge every six months to prevent the buildup of?sulfation, AGM batteries are less prone to sulfation and can sit in storage for longer before a charge becomes necessary. The battery stands up well to low temperatures and has a low?self-discharge.

The leading advantages of AGM are a charge that is up to five times faster than the flooded version, and the ability to deep cycle. AGM offers a depth-of-discharge of 80 percent; the flooded, on the other hand, is specified at 50 percent DoD to attain the same cycle life. The negatives are slightly lower specific energy and higher manufacturing costs than the flooded, but cheaper than the?gel battery. Table 1 compares AGM batteries to gel batteries on key performance characteristics.

No alt text provided for this image
Table 1: Comparisons on AGM and gel batteries

?

Most AGM batteries are mid-sized and range from 30 to 100Ah. They can also be found in UPS, big and small for stationary and deep cycle use. They are commonly built to size and are found in high-end vehicles to run power-hungry accessories such as heated seats, steering wheels, mirrors and windshields. NASCAR and other auto racing leagues choose AGM products because they are vibration resistant.

AGM is the preferred battery for upscale motorcycles. Being sealed, AGM reduces acid spilling in an accident, lowers the weight for the same performance and allows installation at odd angles. Because of good performance at cold temperatures, AGM batteries are also used for marine, motor home and robotic applications.

AGM is making inroads into the start-stop function of cars. The classic flooded type is simply not robust enough and repeated cycling causes a sharp capacity fade after only two years of use.

AGM and other sealed batteries do not like heat and should be installed away from the engine compartment. Manufacturers recommend halting charge if the battery core reaches 49°C (120°F).

Table 2?spells out the advantages and limitations of AGM.

No alt text provided for this image
Table 2: Advantages and limitations of AGM.

source from: Battery Univerisity


No alt text provided for this image

IF NEED BATTERY, CONTACT ME

Company: SHENZHEN POWER KINGDOM

Email: [email protected]

Whatsapp: 0086 17512006750 (Ted Zhou)

Web:www.powerkingdom.com.cn

要查看或添加评论,请登录

Ted Zhou的更多文章

  • PK-010 Basics about Discharging

    PK-010 Basics about Discharging

    The purpose of a battery is to store energy and release it at a desired time. This section examines discharging under…

  • PK-009 How to Charge and When to Charge

    PK-009 How to Charge and When to Charge

    Early batteries were reserved for commercial use only, such as telecommunications, signaling, portable lighting and war…

  • PK-008 Charging at High and Low Temperatures

    PK-008 Charging at High and Low Temperatures

    Batteries operate over a wide temperature range, but this does not give permission to also charge them at these…

  • PK-007 Charging Lead Acid

    PK-007 Charging Lead Acid

    The lead acid battery uses the constant current constant voltage (CCCV) charge method. A regulated current raises the…

  • PK-006 Charging with a Power Supply

    PK-006 Charging with a Power Supply

    Batteries can be charged manually with a power supply featuring user-adjustable voltage and current limiting. I stress…

  • PK-005 What is Equalizing Charge?

    PK-005 What is Equalizing Charge?

    Stationary batteries are almost exclusively lead acid and some maintenance is required, one of which is equalizing…

  • PK-004 Summary Table of Lead-based Batteries

    PK-004 Summary Table of Lead-based Batteries

    The lead acid battery maintains a strong foothold as being rugged and reliable at a cost that is lower than most other…

  • PK-003 Gel Lead Acid Battery

    PK-003 Gel Lead Acid Battery

    The early gelled lead acid battery developed in the 1950s by Sonnenschein (Germany) became popular in the 1970s. Mixing…

  • PK-001 How does the Lead Acid Battery Work?

    PK-001 How does the Lead Acid Battery Work?

    The first sealed, or maintenance-free, lead acid emerged in the mid-1970s. Engineers argued that the term “sealed lead…

  • Precautions for installing UPS batteries

    Precautions for installing UPS batteries

    1. It is forbidden to install ups batteries in a sealed space or near a fire source, otherwise it will cause the danger…