NOX Converters

They won't last forever.

Even though you may have been told that NOx converters do not need to be replaced, Don't Believe it.....

Like everything else that runs at elevated temperatures eventually they will fail and replacement cost are not cheap. Datatek/Thermlcon can recharge or replace used converters for less than one third the price of a new unit.In the case of high temp converters typically they fail due to contamination and what will happen is flow rate and pressure will change affecting the readings and the ratio of O3 to sample inside the measurement cell. Since the restrictions will not change the vacuum indication it looks like all is well. One way to tell if your high temp converter is on the way out is to bypass it and if the readings go up or stay the same in the bypass mode then your converter is crapping out. In the case of MOLY converters remember they are a Consumable and will fail, it's just a question of when. Most manufacturers will tell you to change catalyst every six months but that's not true. Moly converter life is determined by the amount of conversion it actually does not by its time in service. Moly converter life is determined by PPM HOURS and the amount of catalyst used. If a converter is rated for 600 ppm/hrs than running a 1 ppm it will last approx. 600 hours. Using this calculation for a Moly converter to last 6 months running at 10 ppm Nitrogen Dioxide it should be rated a approx. 43000 ppm/hrs, not likely. 

Here's the bottom line, converters need to be changed on a regular basis and we can make it easier and cheaper for you. Send in your spent converter and we will replace or recharge and turn in around within 7 days. I know what you have been told by the vendors, don't believe it!!!Request a RMA number and we will do the rest.

Datatek/Thermlcon

thermlcon.com


bob daversa

Chief Operating Officer at Datatek Systems Inc

7 年

Thanks Brian, glad you liked the post. We (Datatek/Thermlcon} produce a OEM rack mount converter that has a counter feature and well as three flow paths, bypass/moly/moly-high temp. and zero cross over pulsed temp controls. Good little unit. Your right always have a bypass.

回复
Amarendu Sanyal

Analytical Solutions

7 年

Absolutely true, we to are looking for economic recharge of NOx converters

回复
Roberto BELTRAMINI BOVERI

BetaCAP30 | Scientific Measurement, Dynamic gas mixing

7 年

Hi Bob, i remember more than 30 years ago one NOx converter without cathalyzer (just a Pyrex tube heated over 1000 °C) : it was running well, but expensive, big size and not rugged, now not more produced

回复

要查看或添加评论,请登录

bob daversa的更多文章

  • But, you already have one

    But, you already have one

    While bench testing a run of stand alone NOx converters I realized how unfair RATA testing can be. The reason I started…

    7 条评论
  • Linear?

    Linear?

    IT’S THE GAS!I had a chemist the other day show me a response curve for a liquid analyzer that was challenged with…

  • Thanks!

    Thanks!

    Thanks to all for the kind Birthday wishes..

  • Heat Transfer

    Heat Transfer

    To all you thermo dymanic geeks out there, question If (in a perfect world) I have a non-insulated piece of 6061…

  • Baseline

    Baseline

    The word baseline is a term that can be used in most professions and understanding that term is critical for proper…

  • How much did those donuts cost?

    How much did those donuts cost?

    Dealing with large corporations can teach you something about all aspects of business. Ever wonder why a salesman can…

  • Sample Conditioning in CEM applications

    Sample Conditioning in CEM applications

    SIZE DOES MATTER!!!!!!!!! Don’t let anyone tell you that size is not important, especially when it comes to impinger…

  • CEM TEMPERATURES

    CEM TEMPERATURES

    Importance of Temperature control in CEM applications. Most new equipment is temperature controlled and for the most…

  • Should there be a maximum age limit to change trades?

    Should there be a maximum age limit to change trades?

    Was at a site recently and they just got a few new apprentices for I&C tech positions. One of the apprentices was a…

    3 条评论
  • Site Technicians are a dying breed

    Site Technicians are a dying breed

    Just an observation that pretty much spells out what I see happening at most power producers and refineries throughout…

    4 条评论

社区洞察

其他会员也浏览了