LED Sapphire Wafer Quality Control with Hyperspectral Microscopy
Schaefer Technologie GmbH
Your Partner for Scientific Instruments since 1963
Gallium nitride (GaN) based LED sapphire wafers are experiencing explosive growth as they have significant utility in the electronic display market. To meet growing demand, sapphire wafers are now being manufactured in sizes up to six inches in diameter, with a trend toward even larger sizes. The uniform layering of the GaN across the wafer surface produces highly specific reflectance emission on the surface of the wafer for these light-emitting diode (LED) applications.
A critical factor in the production of large sapphire wafers is maintaining consistency of the reflectance emission across the wafer, which is dictated by the homogeneity of the GaN coatings. For both product development and quality control purposes, it is important to understand that the reflectance emission is consistent with regard to the color wavelength peak and the intensity of this peak. This information is often needed across the full diameter of the wafer surface and at high spatial resolution. The ability to analyze the wafer for this information as quickly as possible is a critical requirement.
CytoViva, Inc ’s hyperspectral microscopy system has emerged as a fast and highly effective tool for quickly measuring the peak emission wavelength and wavelength intensity across GaN-coated sapphire wafers. Hyperspectral imaging collects the full spectrum in the VNIR range (400nm-1,000nm) in every image pixel at high spatial resolution, with pixel sizes as small as hundreds of nanometers.
Figure 1 shows a six-inch wafer on the hyperspectral microscope. Using narrow-band UV illumination, the wafer produces a blue reflectance emission, as seen from the image.
The hyperspectral image of the blue LED wafer in Figure 2 is developed using a line scan approach across the selected area of the wafer, and emission data is collected as spectrum in every pixel of the hyperspectral image.
In Figure 3, an example reflectance spectrum from a single pixel is shown. This spectrum illustrates a very narrow emission wavelength with a peak at 460nm.
领英推荐
Figure 4 illustrates the mapping of all image pixels in red that match a preset threshold for wavelength consistency around this 460nm peak.
The interactive tool in Figure 5 shows the parameters set for the threshold wavelength test of the wafer emission spectrum.
In Figure 6, the class distribution report shows the percentage of wafer area that exceeded the threshold measurement.
The illustration above is just one example demonstrating how CytoViva’s hyperspectral microscopy can support both the development and quality control analysis of GaN-coated sapphire wafers for LED applications. To learn more, please contact CytoViva at [email protected] or visit our website at www.cytoviva.com. We would be pleased to discuss your work or to organize a demonstration of the system with your samples.
Visit the Schaefer Technologie GmbH Homepage, Learn More about Different Products from CytoViva and Book a Demo Today: CytoViva | Nanoparticles | Schaefer Group (schaefer-tec.com)