In the previous Learning From Failure article, we reviewed that chloride stress corrosion cracking (Cl-SCC) of stainless steel readily occurs at temperatures above 140°F (>60°C) when exposed to aqueous (water-based) chlorides. Although the most attention is given to corrosion from product exposure, Cl-SCC can also occur from the external surfaces as a result of corrosion under insulation (CUI). Here is an example.

After an insulated buffer vessel containing 176°F (80°C) alkaline polymer leaked, weld repair efforts only opened up additional, undetected cracks within the surrounding area. The vessel comprised of ASME SA-240 Grade 321 stainless steel. It had been in service for fifteen years, located at the Gulf of Mexico coastline and exposed to sea air.

No alt text provided for this image

Panels from the affected region were cut out from the vessel and shipped to Steel Image. Examination found a high density of branched cracks above and throughout a series of stiffener rings. Optical microscopy and energy dispersive spectroscopy (EDS) analysis identified the cracks as chloride stress corrosion cracks (Cl-SCC). Cracking had originated from the external, insulated surface which meant that failure was from corrosion under insulation (CUI).

No alt text provided for this image

No quality issues with the shell material or welds were observed.

Cl-SCC of austenitic stainless is caused by the tirade of aqueous chlorides, temperature and stress. Yet for CUI, the biggest factor to remember is “aqueous” which is just a fancy term to say “water”. The jacketed, insulated external shell surface should be dry and never exposed to water. Without water, you can add as much dry salt as you want and steel won’t corrode. But add water... thus the primary cause of CUI and the resulting Cl-SCC is due to water/moisture getting into the insulation. 

No alt text provided for this image

The buffer vessel failed because the insulation jacketing had not prevented water from getting into the insulation. Once water/moisture wetted the insulation and vessel surface, the combination of temperature, stresses and wet chlorides caused Cl-SCC. The Alkaline polymer solution temperature of 176°F (80°C) meant that ample heat was available such that even low levels of aqueous chlorides would eventually cause Cl-SCC. The chlorides contributing to the cracking were presumed to have been from either the sea air and/or leaching from the insulation. The support ribs tend to be the worse affected areas as water collects/pools on top of them, keeping the insulation wet for longer.

Learning From Failure Series – You can learn a lot from failure… but it is way better to learn from someone else’s failures! LFF uses past failure analysis cases to share lessons learned and review practical aspects of common damage modes suffered in the refining and petrochemical industries.

Learn, share, stay tuned for more!

No alt text provided for this image


Olelewe Chibueze (He/Him)

PhD Researcher || Corrosion Science | Metallic Corrosion | Corrosion Electrochemistry | Metals Characterization and Properties | Oxidation and Degradation of Metals | Metallic Coatings | Hydrogen Interactions with Metals

8 个月

Thanks for sharing

赞
回复
Dhirenkumar Shah

Section Head-Inspection, Asset Integrity at RIL,Ex-HMEL, Certified API571,API 510, API 570, API 653.NDT -LV-II RTFI and UT C&I engineer.

4 å¹´

Thanks for sharing.. I would recommend to use the foil under the insulation material as a protective barrier. It will stop any leached chlorides and aqueous solution in contact to SS substrate.

赞
回复

Thank you for sharing your experience.

Scott Hawkins

Business Development Manager | Account Management, Leadership

4 å¹´
Gaetano Messina

Thermal Mechanical Engineer IBM Retired

4 å¹´

Interesting article, I learned something.

要查看或添加评论,请登录

Shane Turcott的更多文章

  • Start with Understanding "HOW" it Failed

    Start with Understanding "HOW" it Failed

    To understand “why” equipment failed, “how” it failed must be first diagnosed. Different failure modes such as fatigue,…

    21 条评论
  • HTHA Loves Welds #2: How HTHA Affects Steel Integrity

    HTHA Loves Welds #2: How HTHA Affects Steel Integrity

    To operate, inspect and maintain equipment used in hydrogen service requires a practical awareness of how hydrogen…

    5 条评论
  • Why Pipes Burst During Winter

    Why Pipes Burst During Winter

    Earlier I wrote an article about recreating a refinery pipe burst caused by water freezing within a 2” line. This…

    12 条评论
  • How Forging Affects Carbon Steel

    How Forging Affects Carbon Steel

    Earlier this week, I surprised my metallurgical laboratory and engineering team to a blacksmithing course…

    18 条评论
  • High Temperature Hydrogen Attack (HTHA) of Welds

    High Temperature Hydrogen Attack (HTHA) of Welds

    When a plant metallurgist noticed that several of their carbon steels lines had been operating within the Nelson Curve…

    51 条评论
  • It is not the ice that causes pipe bursting

    It is not the ice that causes pipe bursting

    Water freezing within pipes is responsible for many expensive failures. But it’s not the expansion of the solidified…

    46 条评论
  • The Story of a Lucky Scaffolder and HTHA Damage

    The Story of a Lucky Scaffolder and HTHA Damage

    When a reactor was repurposed for hydrogen service twenty years ago, the carbon steel differential lines were no longer…

    29 条评论
  • Death of Duplex: Inspecting for Sigma

    Death of Duplex: Inspecting for Sigma

    There was legitimate concern that the miles of duplex lines on a new offshore rig were at risk of more failures after…

    26 条评论
  • Death of Duplex: Part 3 – Preventing Sigma Phase

    Death of Duplex: Part 3 – Preventing Sigma Phase

    This is the third article in a four part series. Sigma phase is the kryptonite of duplex stainless steel.

    33 条评论
  • Death of Duplex: Part 2 - How Long Before Sigma Forms?

    Death of Duplex: Part 2 - How Long Before Sigma Forms?

    This is the second article of a four part series (extended from three) on the corrosion resistance loss of duplex…

    43 条评论

社区洞察

其他会员也浏览了