Jovvi-Neutron Dosimeter
Model
JV-1021
1021Neutron dosimeter is used for continuous monitoring of environmental neutron radiation.It can also be connected with multiple neutron dosimeters to monitor neutron Radiation in a specific area,so as to provide
The radiation dose rate value in the environment in real time and provide data basis for the management decision of the monitoring center.Can send out sound and light alarm signal according to the predetermined alarm threshold to warn the field staff and ensure their safety.The instrument is imported with high sensitivity 3 He-tube with large size polyethylene ball as a detector,fast reaction speed and good γresistance.
?
Technical Description
Application
1.Suitable for neutron radiation on line dose rate monitoring and alarm in nuclear radiation applications;
The?instrument?is?suitable?for?accelerator?room,environmental
protection,chemical?industry,?petroleum,
medical?treatment,import and?export
commercial?inspection,nuclear?power,
neutron?source?and?other?security?check,
border?control,customs?inspection?and
other?neutron?radiation?detection
occasions.
2.Use 3-He-tube with large volumes low for better energy response and sensitivity;
3. With the upper computer software communication interface,it can be fixed and installed in the radiation application site to be monitored.
4.Through wireless or the wired network summarizes the real-time dose rate,information?into?the?monitoring?computer?system?to?for?ma?regional?radioactivity?monitoring?network;
5.It?can?be?used?alone?and?flexibly?placed?in?the?office?or?carried?around;
6.It?can?set?the?alarm?threshold?by?yourself,and?output?the?alarm?signal?through?the?field?sound?and?optical?alarm;
7.Equipped?with?a?large-size?high-definition?touch?screen,real-time?display?of?measurement?value,measurement?unit?and?other?information;
8.With?the?backup?battery,keep?the?equipment?to?continue?to?work for?no?less?than?8hours?when?the?power?is?cut?off;
9.Energy?range:neutron0.025eV~16MeV;
10.Measuring?range?of?the?neutron?dose?rate:0.1μSv/h~100mSv/h;
11.Relative?inherent?error:±15%;
12.Neutron?sensitivity:greater?than1.4CPS/μSv/h;
13.γ?sensitivity:the?no-response?threshold?is?not?lower?than 25μGy/h;
14.Use?environment:temperature-15℃~+50℃,relative?humidity(at40℃temperature)95%;
15.Protection?level:IP65;
16.Weight?and?size:about350250245(mm),about9.8Kg;
17.Accessories:supporting?charger,suitcase/strap,etc.
#nuclearmedical#radiotherapy #cyclotron #petct #petmr#mri #xray Born To Strive -SALES-MUSICIAN-ARTIST of LIFE