Integral Meter Run Assembly
John Kingsley
ICS/OT Cybersecurity Practitioner | R&D | Product Security | Threat Modelling | Security Architect | OT GRC | Community Builder | LLM & AI in Cybersecurity
Integral Flow Orifice Assembly is used Differential Pressure Transmitter has to be directly mounted on the orifice assembly. This eliminates cost of installation of Differential Pressure Transmitter with impulse piping up to the orifice assembly. The transmitter is mounted on the orifice assembly through a 3/5 Valve H-type manifold. Available with line sizes of 2" & below. However due to process temperature limits of the transmitter, this assembly cannot be used for process temperatures above 120 Degrees Centigrade. The assembly consists of a orifice plate between two integral blocks having corner tap. Generally meter run pipe is recommended with upstream length of 750mm and downstream length of 250mm. The pipes are welded to the blocks with end flange.
Advantages of using Integral Meter run assembly
- Use of an integral orifice flow meter will eliminate the three measurement inaccuracies recorded in small orifice line installations.
- The Integral Orifice honed body reduces ID uncertainty
- By inserting precision bored upstream and downstream sections of pipe, the velocity profile distortion due to pipe roughness is reduced.
- The self-centering design of the Integral Orifice Plate eliminates plate misalignment.
Specifications
Improves reliability and maintenance costs
The integral orifice flow meter eliminates impulse lines, reducing leak points by over 50% and decrease start-up time due to the flexibility of numerous process connection options. The direct mount design minimizes line plugging by eliminating long lines, small-bore ports, and crevices while providing consistently reliable installations.
- Accuracy up to ±0. 5% of volumetric flow rate
- Integral manifold head allows direct mounting of DP transmitters
- Ideal fluid types: liquid, gas, and steam
Meter runs are supplied as a complete unit of normally 1M length to ensure the necessary straight pipe length to achieve highest possible efficiency.
These are available with line sizes mostly below 50mm with corner tap.
These are used for the measurement of small flow rates precisely where high accuracy of low rates is required.
Types of Meter Runs:
1. Orifice Flange union with Meter -run.
2. Orifice flange union with Carrier ring & Meter –run.
Generally Meter-run pipe is recommended with upstream length of 750mm and downstream length of 250mm.
Meter runs sizes above 50mm are also available as per the customers or process requirements.
MOC: Orifice Plate in SS 316, SS 304 & other on request.
End Connection: Socket Weld, Screwed and Flanged ends with meter run piping suitable to ANSI, IS & DIN flanges
Further Reading
Restriction Orifice (RO) – Flow Control Instrument
Difference between Orifice & Restriction Orifice
iFluids Engineering - Process Engineering, Design and Studies, Instrumentation, Piping, Mechanical, Structural Design Services >> To know more drop an email to [email protected]
>> To know more drop an email to [email protected]
Disclaimer: All information and content contained in this website are provided solely for general information and reference purposes. TM information, Images & any copyrighted material inadvertently published or depicted belong to rightfull owner and iFluids doesnt claim to be its own.
Market Communicator
5 年This report research the worldwide Flange market size (value, capacity, production and consumption) in key regions like United States, Europe, Asia Pacific (China, Japan) and other regions. Get Sample Copy of This Report @ https://bit.ly/2Xx5Vm6?