In-Row, Room, and Rack Cooling: Choosing the Right Solution for Your Data Center

In-Row, Room, and Rack Cooling: Choosing the Right Solution for Your Data Center


Background

Data centers hold massive amounts of information in the modern era. One of the most critical factors to ensure that they run optimally is through cooling. How is that done?


Introduction

Efficient thermal management is a cornerstone of effective data center operations. With increasing computational demands, maintaining optimal temperatures and humidity levels is crucial to prevent equipment overheating and ensure continuous operation. Cooling solutions can be broadly categorized into in-row, room, and rack cooling units, each with distinct features and advantages. Understanding these differences helps data center professionals choose the most suitable cooling method for their specific needs.


Room Cooling

Room cooling systems are designed to control the temperature and humidity of an entire room. These systems include air conditioning systems that distribute cooled air throughout the data center. Key features include:

  • Wider Coverage: Room cooling systems are effective for managing the overall thermal environment of a data center, providing consistent conditions across the entire space.
  • Cost-Effective for Large Spaces: Room cooling can be more economical and practical for data centers with lower rack densities or larger physical spaces.

Vertiv Liebert? SRC installation. Image Courtesy of Vanguard Powersol.

Room cooling suits data centers with lower rack densities or those needing a consistent environment across a large area. An example of such a unit is the Vertiv SRCs. For environments where indoor space is at a premium, the Liebert? SRCs offer a unique solution. These wall-mounted thermal management solutions are suitable for small critical rooms where uninterruptible (24x7) cooling is the prime focus. The Vertiv? Liebert? HPM on the other hand, are designed for larger rooms.

In-Row Cooling Units

In-row cooling units are placed between server racks within a row, directly targeting the heat generated by the servers. These units are positioned near heat sources to ensure efficient cooling ensuring an optimal operating environment for critical data center infrastructure. In-row cooling offers several benefits:

  • Localized Cooling: By placing the cooling units close to the heat sources, in-row cooling ensures efficient heat removal and minimizes the risk of hot spots.
  • Scalability: This approach allows for modular growth. Additional cooling units can be added as the number of server racks increases, providing flexibility in managing evolving cooling needs.
  • Energy Efficiency: In row-based cooling, the airflow paths are shorter and more clearly defined, reducing the unit’s fan power required and increasing efficiency.
  • Targeted Cooling and Redundancy: A row-oriented design allows cooling capacity and redundancy to be specifically tailored to the actual needs of individual rows, enhancing overall system reliability and efficiency.

Vertiv Liebert? CRV installation. Image Courtesy of Vanguard Powersol.

An example of such a unit is the Vertiv CRV. The Vertiv? Liebert? CRV is a row-based thermal management solution that provides maximum cooling efficiency within a compact footprint. Ideal for high-density applications, the CRV is designed to effectively remove heated air from data centre environments.

Rack Cooling Solutions

Shield rack cooling solution. Image courtesy of Vanguard Powersol.

This solution integrates directly into individual server racks, providing targeted cooling at the source of heat generation. These units are also positioned near the heat sources to offer maximum efficiency. These solutions offer several advantages:

  • Maximized Cooling Efficiency: By cooling at the rack level, these systems ensure that heat is immediately dissipated, which is critical for high-performance computing environments.
  • Enhanced Control: Rack cooling units allow for precise temperature management of each rack, accommodating varying thermal loads across the data centre.
  • High-Density Applications: Ideal for environments with extremely high heat densities, such as blade servers or high-performance computing clusters.
  • Efficient Airflow Paths: In rack-oriented cooling architectures, the cooling units are dedicated to one server rack and are directly mounted to or within the racks. This setup creates shorter, more precisely defined airflow paths, achieving the highest power density.
  • Increased Efficiency: Similar to row cooling, the reduced length of the airflow path in rack cooling reduces the CRAC (Computer Room Air Conditioner) fan power required, thus increasing overall efficiency.
  • Targeted Cooling and Redundancy: Rack-oriented cooling allows cooling capacity and redundancy to be specifically tailored to the actual needs of specific racks of servers.

Rack cooling mainly benefits data centres with high-performance, high-density equipment that generates significant heat. At Vanguard Powersol we have a variety of rack cooling solutions in Huawei, Shield and Vertiv brands.

Conclusion

Effective thermal management is essential for data centre reliability, efficiency, and longevity. Each cooling solution—in-row, room, or rack cooling—offers unique benefits tailored to different operational needs. In-row cooling provides precise, localized cooling for high-density environments, allowing for modular growth and enhanced energy efficiency. Room cooling offers broad coverage and centralized management, ideal for spaces with lower rack densities. Rack cooling delivers targeted, high-density cooling with maximum efficiency and control, making it perfect for high-performance computing environments. Choosing the right cooling solution involves considering factors such as density and heat load, scalability needs, budget constraints, and maintenance requirements. High-density data centers with significant heat output may benefit from the precision of in-row or rack cooling. Lower-density environments might find room cooling more practical. In-row cooling systems offer modularity, making them suitable for data centers expecting significant growth or fluctuating thermal loads. By understanding the strengths and applications of each cooling method, data center managers can make informed decisions that ensure optimal operating conditions, enhance performance, and support the long-term sustainability of their critical infrastructure.


Article by faith Munene