Implement OMRON PLC CP1L-EL to ThingsBoard through BLIIOT Industrial Intelligent Gateway BL110

Implement OMRON PLC CP1L-EL to ThingsBoard through BLIIOT Industrial Intelligent Gateway BL110

BL110 Gateway Collects OMRON PLC CP1L-EL Data Through Ethernet Port.

Add OMRON PLC?via Ethernet Port

OMRON PLC data can be collected through WAN, LAN and cascaded switch.

1.?LAN?Port Configuration

Below is example of adding OMRON PLC CP1L-EL to LAN port. Configure it as below.

No alt text provided for this image

  • Double click LAN to enter configuration box.
  • DHCP: enable auto IP distribution. Default is disabled.
  • Routing: Enable network routing function. Default is disabled. For example, PLC CP1L-EL?does not need network. Thus it’s necessary to enable it.
  • IP Address: defaut is 192.168.3.1, the IP addresses assigned to LAN port devices must be within the range. WAN and LAN IP address can’t be the same. For example, CP1L-EL?IP is fixed, then change IP address of gateway.
  • MAC Addres: Input LAN port MAC address.
  • Click OK to confirm it.

Note: Click Save Data and Gateway will restart.?Turn off the power of Gateway and restart it. After that LAN port configuration is done successfully

Note: LAN Port IP Address specifies the IP address arrange of LAN port device. If device IP address is not within the range, data can’t be collected. Thus it’s necessary to change LAN port IP address according to requirement. IP Address change will not be effective until gateway is powered?off and powered on again?

2. ?Add OMRON PLC CP1L-EL?to LAN Port

No alt text provided for this image

  • Click LAN and right click mouse?and click Add?to enter device configuration box.
  • Device Name: set device name, for example, set CP1L-EL?as device name.
  • Device IP: input PLC?IP address. For example, PLC CP1L-EL?IP is 192.168.3.151, thus put 192.168.3.151 here. This is PLC IP address. PLC IP address and LAN Port IP address must be in the same range.
  • Device Port: input LAN port device port. CP1L-EL?default port is 9600
  • Device Brand: Select Siemens as Device Brand and select CP1L-EL?as device model.
  • Click OK to confirm adding PLC CP1L-EL.

Note: CP1L-EL?device icon will appear after confirming the configuration. If more devices?to be added, perform the same procedure as Step.

Note: Click Save Data and gateway will restart automatically. After restarting, PLC CP1L-EL?is added successfully.?

3. Add LAN Port OMRON PLC CP1L-EL?Datapoint

Below example is part of PLC CP1L-EL register CIO & D data configuration.

No alt text provided for this image

  • Click CP1L-EL, move mouse cursor to the right box, right click the mouse and click Add to enter datapoint configuration box.
  • Variable Name: Set the name of datapoint, for example, D100.
  • Variable Unit: set any unit according to actual requirement.
  • Address Type: select address type according to PLC register. Here D100 address type is D.
  • Starting Address: Register address of datapoint. Here D100 address is 100.?
  • Data Type: select data type according to PLC register type.
  • Adding Qty: If addresses are consecutive, the same register will collect multiple addresses.
  • Read-Write Type: select from Read only and Read & Write.
  • Ratio: set the ratio to be multiplied or minified for uploading to cloud.
  • Modbus Mapping Address:?Set address where datapoint will be saved in BL110.

Modbus mapping address can be any from 0 to 2000 and it can’t be repeated.

For example, set 27 as D100 mapping address.

  • MQTT Flag: It can be any identification mark and can’t be repeated.?For example: D100.
  • Click OK to confirm.

Note: After confirming the configuration, datapoints will appear in the box like above picture. To add more datapoints, right click the box and click Add to enter configuration box. Perform the same procedure as Step .

Note: Click Save Data. Gateway will restart automatically?and CP1L-EL?datapoint is added successfully.

4.?Connect to ThingsBoard

BL110 collects data of different protocols. The configuration procedures of uploading data to various clouds are the same. Here only introduce configuration of collecting PLC data and send it to various?