The Impact of the Revised Annex-I on Sterile Product Manufacturing
Nikhil Kulkarni ASQ CQA
Senior Manager Global Quality | GXP Quality Auditor | Supplier Quality
The revised Annex 1 becomes effective on August 25, 2023, except for section 8.123, which mandates sterilization for manually loaded or unloaded lyophilizers without barrier technology. This section will be effective from August 25, 2024.
This new annex significantly impacts sterile product manufacturing, introducing several new requirements and clarifying previously ambiguous aspects. Given the document's complexity, expert interpretation is necessary. This article highlights and discusses the main changes.
Key Changes in Annex 1
Despite the unchanged goal of reducing contamination in sterile products, three new concepts have been incorporated into the scope and opening sections:
Non-Sterile Laboratory Practices: Specific points from the legacy Annex 1 are now explicitly included, making practices like cleanroom classification and microbiological control limits more meaningful.
Quality Risk Management (QRM): The annex now emphasizes a reinforced QRM approach across all activities, making it essential for procedures, equipment, facilities, services, personnel, and processes.
Contamination Control Strategy (CCS): CCS is now a mandatory document, defining all critical control points and measures to assess and control contamination risks.
Premises
The new annex places a strong emphasis on using new barrier technologies to prevent contamination from materials or personnel shredding in Grade A areas. There is another change in the section of the premises. Now, Grade A is considered a critical zone for high-risk operations, whereas Grades B, C, and D are considered cleanrooms. This classification is achieved by using unidirectional airflow in Restricted Access Barrier Systems (RABS) or isolators.
To achieve this, the access of personnel into the Grade A area should also be limited through the design of facilities, equipment, processes, and procedures. Air pressure differentials must now be continuously monitored; and there must be an alarm system in case of out-of-limit values. In contrast, the legacy version only required this to be recorded periodically.
The new annex recommends separating personnel airlocks for entry and exit from those used for the movement of materials between different areas or cleanrooms. The annex also recommends having an interlock mechanism in place for Grade A and B areas, although it would seem logical to apply this principle to all cleanroom grades. Please note that the entry and exit doors of airlocks leading to Grade A and B areas should not be opened simultaneously. This can be achieved by using an interlocking system. However, in the case of airlocks leading to Grade C and D areas, a visual and/or audible warning system is sufficient. If the CCS indicates a high risk of cross contamination, the annex states that separate changing rooms for the entry and exit of personnel should be considered.
Personnel that enter the space should flow from lower to higher grade areas of increasing cleanliness (for example, from Grade D to C, from C to B, and then from B to A). However, the new annex does not state the flow of personnel who leave the space, which potentially allows for skipping grades on the way out. The movement of materials from lower-grade cleanrooms to higher-grade areas should be subject to cleaning and disinfection, depending on the risk and the CCS.
Airflow patterns and complex gas flows within cleanrooms and zones should be visualized to demonstrate that air does not ingress from lower grade (i.e., more contaminated) to higher grade (i.e., less contaminated) areas.
The new annex strongly focuses on environmental monitoring since continuous cleanroom monitoring and environmental monitoring is the most effective way of reducing contamination risk. However, this should not be a substitute for poor environmental control. It means that Quality by design and risk assessment principles need to be introduced in the process design beforehand. Cleanroom monitoring should be part of the overall CCS. The controls and monitoring practices are to be based on sound scientific reasoning and should be able to effectively assess the cleanroom environment, airlocks, and pass-through hatches. Ensure that these conditions are properly monitored and evaluated.
It is obvious that cleanrooms and clean air equipment must be classified and qualified for the manufacture of sterile products. However, the legacy document did not define what tests would need to be executed for this. For the first time, the new annex includes a list of tests to perform for the qualification of cleanrooms. Qualification should include testing for: filter system, airflow, air pressure, microbial contamination, temperature, humidity, recovery, and containment leak. The classification of cleanrooms is based on the total particle concentration limits (at 0.5 microns and 5 microns), and is part of the cleanroom qualification process. The initial classification should be performed during simulated operations in both “at rest” and “in operational” states. In addition, the qualification of cleanrooms is completed by the determination of microbial contamination level. The number of samples taken and their sampling locations should depend on the risk assessment. The legacy annex included microbial contamination limits for the monitoring of clean areas or areas in operation. The new annex specifies that the microbial concentration level must be determined during qualification both “at rest” and “in operation” and must be verified.
There are two changes in the maximum permitted microbial contamination levels appearing in the new annex i.e. ?The average calculation of results is not considered in the table and No growth of microbial contamination should be seen for Grade A cleanrooms. The annex specifies for the first time the frequency or maximum time interval for qualification: 6 months for Grade A and B areas; and 12 months for Grade C and D areas. The document also requires the maximum number of people present in the clean area during operation. Requalification is also needed whenever there is a change to equipment, facility, or process, and based on the change management process. Moreover, it is not enough to qualify or validate facilities, equipment, and processes. Continuous verification and regular reviews must be conducted.
The new annex places a stronger focus on cleaning and disinfection protocols. Cleaning needs to take place before disinfection. However, cleaning must not leave residues, as these may interfere with disinfectants. Different types of disinfectants can be used, as they have different modes of efficacy in order to increase the spectrum of disinfection. A sporicidal agent must be included in the disinfection plan across all grades of cleanrooms. The disinfection process must be supported by the use of validated disinfectants and be assessed through the environmental monitoring program, including different types of organisms that are potentially resistant. The annex requires any disinfectant that is diluted to be assessed for its microbial content, including hold times and expiry times. The text requires that disinfectants and detergents used in Grades C and D may also require sterilization when determined by the CSS. When they are prepared by the manufacturer, microbial contamination should be monitored by the supplier; when supplied “prediluted”, the supplier’s certificates of analysis can be accepted as long as the supplier is qualified. The cleaning validations should respect the expiry dates of the prepared solutions
Equipment
Some points of the equipment section have been expanded in the new annex to provide general guidance on the design and operation of equipment: A detailed description of equipment and services (process and instrumentation diagrams) should be available at the initial qualification and kept up to date as part of the continuous review of the CCS. Process and equipment alarms should be evaluated for trends. Direct and indirect product contact parts (parts in contact with sterilized critical components) should also be sterilized. Particle counters, including their sampling tubing, should be qualified. The new annex specifies that the length of the tubing must not exceed 1 meter and should have a minimum number of bends.?
Utilities
The previous annex did not go into much detail on utility systems such as gas, water, and vacuum. The new annex incorporates the following requirements: The criticality of each utility system needs to be assessed as part of the CCS and covered by a risk assessment. Higher-risk utilities in descending order of criticality include: Major risk: Utilities that directly contact product, such as water for washing and rinsing, gases, and steam for sterilization. Utilities that contact materials that will ultimately become part of the product. Utilities that contact surfaces that come into contact with the product. Other utilities that may directly impact the product. Results of critical parameters and Critical Quality Attributes (CQA) of high-risk utilities need to be trended regularly to ensure the system’s suitability. For example, trends of pressure differentials, steam Quality, and water Quality. Pipes and ducts are to be avoided in cleanrooms. Our interpretation of this requirement is to minimize their impact on the cleanliness and contamination control of the environment. Cleanrooms need to be designed with minimal airborne and surface contamination, so the presence of pipes, ducts, and other utilities that penetrate the walls or ceiling can introduce contaminants from other areas into the cleanroom.
The requirements for water systems focus on actions that prevent microbiological contamination, particulate matter, and endotoxins/ pyrogens. Water for injections (WFI) that is free from microorganisms, particulates, and endotoxins should comply with the current monograph of the European Pharmacopeia. Water should be in constant circulation at a temperature above 70oC to maintain Quality and minimize the risk of microbiological growth. Special care should be taken for microbial contamination from vent filters installed in storage tanks. Legs in pipelines should be avoided wherever possible. Biofilm formation is another challenge. The risk of microbial adhesion and biofilm formation in the pipes can be minimized if the water flow is turbulent, and sterilization, disinfection, or regeneration of water systems is planned. Special care should be taken due to seasonal variation. After disinfection is done, testing must be carried out before using the water system. Continuous TOC and conductivity monitoring must be in place in WFI systems. These values can indicate the performance of the water system and alert probable excursions before they happen, Values exceeding the alert levels should be documented and include a trend analysis to determine if this is an isolated event or if it is indicative of loss of control or deterioration of the system. The root cause and impact on the Quality of products or processes in which it is involved should be determined.
Pure steam generators must be designed, qualified, and operated in such a way as to comply with the defined specifications of chemical substances and endotoxins. When steam is used as a direct sterilization agent of materials or surfaces in contact with the product, the condensates must comply with the current EP monograph for WFI. A regular sampling plan must be in place to ensure representative samples of pure steam are tested for analysis in which additionally non-condensable gases, dryness value and superheat must be analyzed.
Gases that come into direct product contact must be of the appropriate chemical, particulate, and microbial Quality, including oil and water content. The design of the gas and vacuum system should prevent backflow to avoid potential risks of contamination. In the case of gases used in aseptic processes, an additional filtration step is needed to remove basic bacteria. A sterilizing grade filter with a pore size of a maximum of 0.22 microns needs to be used at the point of use.
领英推荐
There is a risk of spillage and cross-contamination with heating, cooling, and hydraulic systems. To avoid this risk, it is recommended that they are placed outside the filling room. In the event of leakage, a warning alarm should be in place.
Personnel
The basic requirement of having trained, qualified, and experienced personnel with a focus on sterile product protection is maintained in the annex. It is the manufacturer’s responsibility to ensure that sufficient appropriate personnel is available. Particular importance is given to training, specifying the areas in which relevant staff must be trained: hygiene, microbiology, cleanroom practices, contamination control, aseptic techniques, behaviours, gowning, and protection measures. The training should be comprehensive, being in accordance with the criticality of the activities and areas of work to be carried out by each person. The entry of non-qualified personnel to Grade A and B cleanrooms in operation is restricted. For exceptional cases where access is necessary, written procedures outline the situations in which access is allowed and what steps are to be taken, including direct supervision by a qualified and authorized person. Clothing with low particle shedding is required. Appropriate garments for sterile areas must be worn prior to entry to Grade B areas and visually inspected for their integrity. Reusable clothing must be cleaned using a qualified procedure that ensures clothing is not damaged and contaminated. The annex mentions that personnel qualification procedures and a disqualification system must be in place. To reinstate a disqualified employee for aseptic practices, retraining and requalification is required.
Production and Specific Technologies
Not much has changed regarding production technologies for terminal sterilization. The CCS should identify the risks of contamination in different areas and cleanrooms. If a high risk of contamination has been identified in the processing of bulk solutions, a filtration step should be used to reduce the bioburden levels prior to the filling process. The cleaning of primary packaging containers and components should also be validated. The new annex encourages the use of RABS, isolators, and robotics to reduce the risk of contamination and the need for human interventions.
Human interventions during aseptic processing are serious issues. They can increase the risk of introducing contamination into the aseptic filling area. The new annex requires that human interventions are carefully designed, evaluated via risk assessment, and qualified. Interventions can disrupt first air. So, we can say that the best practice is to avoid any kind of intervention whatsoever. If this is not possible, we should limit the number and complexity of human interventions as much as possible. Non-qualified interventions should be performed exceptionally with the authorization of the Quality unit, which should perform a risk assessment, an investigation, and an evaluation prior to batch disposition.
The new annex includes a large section on sterilization technologies: Sterilization by heat Moist heat sterilization Dry heat sterilization Sterilization by radiation Sterilization with ethylene oxide Filter sterilization The following guiding principles are essential: Use scientific principles in the selection of the sterilization procedure. Validate the sterilization process - repeatability and reliability - by physical measurements and biological indicators. Use heat sterilization, which is the preferred system; otherwise use another method described in the current European Pharmacopeia. There are some concerns with the use of ethylene oxide. It should only be used when no other method is practicable, because of the difficulty to ensure that no residues or reaction products are controlled at acceptable limits. Review and verify the sterilization process at scheduled intervals according to the risk assessment and CCS. Deviations must be investigated. Sterilization records should be reviewed and approved for batch release purposes by a knowledgeable person.
Environmental and Process Monitoring
As an important verification tool in the CCS, the environmental program will ensure the air cleanliness of cleanrooms and equipment and will detect deviations from established acceptance criteria. All controls are effective when they are considered holistically and not individually. The guidance applies to ongoing routine monitoring. Environmental monitoring comprises the following
·????? Particle monitoring (the particle monitoring program should be risk-based to establish sample locations, types of samples and methods selected, samples sizes and volumes, sampling time, frequency, and strategy for personnel monitoring)
·????? Viable particle monitoring
·????? Temperature monitoring
·????? Relative humidity monitoring
·????? Aseptic process simulation (APS) or media fill.
These parameters are good indicators of the areas’ cleanliness and their good aseptic processing conditions. Temperature and humidity are important environmental parameters that can affect the stability and shelf life of the product. It can also impact the growth and survival of microorganisms, which can pose a risk of contamination to the product. It is important to note that the annex considers positively the use of rapid monitoring methods, appropriately validated, which speed the early detection of microbial contamination.
Alert levels and action limits need to be established based on qualification tests. Trending data should be reviewed periodically. In the case of having out of alert/ action limits, they should be investigated to find the root cause and apply appropriate CAPAs.
The annex describes that APS or media fill is periodic verification effectiveness that should be done based on Risk Assessment of the aseptic process (e.g., qualification, validation, or after changes). APS should cover aseptic manipulations and interventions, as well as worst-case scenarios. All routine monitoring data obtained in production should be trended and used as part of the routine batch release and periodic assessments. Trends should include different types of excursions, such as increasing numbers of excursions, consecutive excursions, isolated excursions, or changes in microbial patterns.
Quality Control
The QC part of the annex includes requirements on QC/QA personnel training and experience, Specifications, Types of microbiological tests (e.g., bioburden or sterility), Sampling, Method verification/validation, Parametric release, Data review.
Final Considerations
In the end, it is important to recognize that the Annex only sets out the minimum requirements. Pharmaceutical manufacturers should continually focus on preventative strategies, including proactive risk assessments and controlled changes, supported by trending, investigations, corrective and preventive actions (CAPA), root cause determination, and the use of robust investigational tools. Producing sterile medicinal products is all about continuous improvements.
Sr. Manager QA
9 个月Insightful. Thanks for posting..
Deputy Manager QMS, Certified Auditor, Qualified Investigator & GMP Trainer at Apotex Inc. (GBS)| Ex-TCS | Ex-Viatris (formerly known as Mylan Labs Ltd)
9 个月Thanks for sharing
Pharmaceutical Quality Assurance professional
9 个月Thanks for sharing
DGM-Global Quality Management at Amneal Pharmaceuticals ( Supplier Quality, GMP-GxP Auditing, Compliance, External Manufacturing Compliance (CMO management)
9 个月Interesting! Welldone buddy
Helping Davids Beat Goliaths | Marketing Consultant | Market Researcher | Branding & Content Strategist | B2B Brand Growth Expert | Cross-Industry Credentials | Increased Agency Revenue 25% YOY |
9 个月your insights on the revised annex 1 are invaluable for staying compliant and ahead of the curve. Nikhil Kulkarni ASQ CQA