Hydrogen Induced Cracking (HIC) and HIC Test fee

Hydrogen Induced Cracking (HIC) and HIC Test fee

  1. What’s Hydrogen Induced Cracking Test - HIC Test?

Hydrogen-induced cracking (HIC), also referred to as hydrogen stress cracking or static fatigue, is a typical form of hydrogen embrittlement. It is characterized by the brittle fracture of a normally ductile alloy under sustained load in the presence of hydrogen. More often, fracture occurs at sustained loads below the yield strength of the material. This cracking mechanism depends on the hydrogen fugacity, strength level of the material, heat treatment/ microstructure, applied stress, and temperature. Many ferrous and nonferrous metals may be susceptible to hydrogen damage in both aqueous and gaseous hydrogen-bearing environments. These metals includes carbon steel, alloy steel, and nickel & nickel alloy, etc.

No alt text provided for this image

2.  How to calculate the fee of HIC test?

Sometimes, clients ask to quote HIC test fee but without telling us how many heat number do they need. Then supplier can only quote clients the HIC test fee per heat number. Clients can calculate the total HIC test fee according the heat number they need.

No alt text provided for this image
No alt text provided for this image

HEBEI CANGHAI NUCLEAR EQUIPMENT TECHNOLOGY CO.,LTD. is a Manufacturer for steel pipe fittings in China since 1976.

We produce BUTWELD FITTING: Elbow, bend, tee, reducer, cap and pipe, flange etc.

1. Supplier of Technip, Fluor,BP, TC CONCEPT, SONATRACH, NIGC, YADAVARAN OIL FIELD, PDVSA, IOCL.......

2. What we supply: pipes, butt weld, socket weld, threaded fittings, pipe and flanges etc.

3. Sizes range from 1/8'' to 60'' and can be made customized.

4. Materials are: Carbon Steel, Alloy Steel, and Stainless Steel.

5. Certificate we have: ASME, ISO, API, CE, CCSC,NB, OHSAS...