How to read a pump performance curve remains a topic of great interest across the?food,?dairy,?beverage, and?pharmaceutical?processing industries, so in this post we provide important information on two of our most popular styles —?Centrifugal?and?Positive Displacement.
A pump performance curve helps you select the right pump for the specific needs of your application.
With manufacturing lead times growing, selecting the right pump the first time is more important than ever. At the same time, understanding the full range of each pump’s capabilities under specific operating conditions gives you a window to your options, so you’re not locked in to just a few choices during the selection process.
Also called a pump selection curve, pump efficiency curve, or pump performance curve,?a pump curve chart gives you the information you need to determine a pump's ability to produce flow under the conditions that affect pump performance. Reading pump curves accurately helps you choose the right pump based on application variables such as:
A pump has to produce enough pressure differential to overcome head loss created in pipe systems by friction, valves, and fittings.?A pump curve shows the two performance factors on the X, Y axis so you can see the volume of fluids a pump can transfer under various pressure conditions.?
This pump curve explanation also discusses variables such as:
For example, if you know the flow rate your application requires, you find the gallons per minute (or hour) rate along the bottom horizontal line of the curve and then draw a line up to the head/PSI you require.?The curve will show you if the pump you have selected will perform in that application.
WHAT IS HEAD?
Head is the height to which a pump can raise water straight up.?Water creates pressure or resistance, at predictable rates, so we can calculate head as the differential pressure that a pump has to overcome in order to raise the water.
Common units are feet of head and pounds per square inch. (A pump curve calculator might offer different units such as Bar or meters of head). As the chart below illustrates, every 2.31 feet of head equals 1 PSI.
THE FORMULA FOR PSI: FEET OF HEAD/2.31 = PSI
Flow is the volume of water a pump can move at a given pressure. Flow is indicated on the horizontal axis in units like gallons per minute, or gallons per hour, as shown in the curve below.
A basic pump performance curve for centrifugal pumps show it's performance range. In the above curve, head is measured in PSI; flow is measured in gallons per hour.?Given the relationship between head and PSI, we can look at the sample curve in another way and say that at 184.8 feet of head (80 psi X 2.31 feet), the pump will generate a flow rate of 1321 gallons per hour.
WHAT IS TOTAL DYNAMIC HEAD?
While pump curves help you select the right pump for the job, you first have to know the total dynamic head for the application.
Total Dynamic Head (TDH) is the amount of head or pressure on the suction side of the pump (also called static lift), plus the total of 1) height that a fluid is to be pumped plus 2) friction loss caused by internal pipe roughness or corrosion.
TDH = Static Height + Static Lift + Friction Loss
HOW TO USE PERFORMANCE PUMP CURVES IN SELECTING EQUIPMENT: THE BASICS
Let's say you want to know the flow rate you can achieve from the pump in curve below at 60 Hz when the design pressure is 80 PSI. In this case, the curve shows that the pump can achieve a flow rate of 1321 gallons per hour at 80 PSI of discharge pressure.
In the above pump performance curve, the pump can generate 80 PSI of discharge pressure at a flow rate of 1321 gallons per hour. Pump curve charts indicate flow rates on the horizontal axis and pressure on the vertical axis.
READING CENTRIFUGAL PUMP CURVES THAT CONTAIN ADDITIONAL INFORMATION
Because some centrifugal pumps operate across a range of horsepower, their curves will include additional information. The curve below, for example, features a pump that can operate from 2 to 10 horsepower depending on desired performance.
Variable Horsepower pumps can operate at a range of head/flow combinations and impeller trim sizes.
For additional curves, see?Alfa Laval LKH performance curves.
IMPELLER TRIM SIZE
Impeller size is another variable for meeting performance requirements. The curve above shows impeller trim sizes, at the right end of each curve, ranging from a minimum of 4.33" to a maximum of 6.42".
Reducing impeller size enables you to limit the pump to specific performance requirements. The curve above shows maximum pump performance with a full-trim impeller, minimum pump performance with a minimum-trim impeller, and performance delivered by the design-trim impeller, or the impeller trim closest to the design condition. Impellers are typically trimmed 0.20 inches (or 5mm) at a time.
Impeller size is also a factor when handling?shear sensitive?liquids, or liquids that change viscosity when under pressure.
NET POSITIVE SUCTION HEAD REQUIRED/AVAILABLE
In addition to pressure and flow, the curve at the bottom of the curve above indicates NPSHr, which stands for Net Positive Suction Head Required.?NPSHr is the minimum amount of pressure required on the suction side of the pump to avoid?cavitation, or the introduction of air into the fluid stream. NPSHr is determined by the pump. You always want NPSHa>NPSHr.
NPSHa, with "a" standing for?available, is determined by the process piping.?
You always want NPSHa to be greater that NPSHr. Without enough net positive suction, the pump will cavitate, which affects performance and pump life.
EFFICIENCY AND PERFORMANCE VARIABLES
Good pump efficiency means that a pump is not wasting energy in order to maintain its performance point.?No pump is 100% efficient, however, in the work it has to do to transfer liquids.
When selecting a pump and motor combination, consider not only the total current demand but future demand to ensure your selection has the capacity to meet changing requirements. To that end,?sizing the pump for performance variables rather than peak efficiency is a common practice.
For example,?while the middle of the pump efficiency curve is generally where a pump is operating at maximum efficiency in terms of pressure and flow rate, moving right on the curve above shows an increase in horsepower needed to maintain a flow rate as head increases. For example, 2 hp is required for a flow rate of 40 gpm with 80 feet of head, but maintaining 40 gpm of flow at 110 feet of head would require a 3 hp motor.
You can audit pumping systems using?pump performance characteristics. Once you determine the best efficiency point (BEP) for your application, you can make adjustments to improve overall system efficiency, such as adding a variable frequency drive (VFD) and changing the diameter of the pump impeller. Controlling flow rate by adjusting pump speed via VFD instead of pressure valves can result in better efficiency and greater energy savings.
When using pumps in parallel, you can increase flow rate at the same rate of head.?As the image below illustrates, using pumps in parallel gives you a flow rate that is the sum of pump A and pump B’s flow rates.
Finally, variable speed pump curves show flow rates at various RPM, as shown in the curve below.
2. HOW TO READ A POSITIVE DISPLACEMENT PUMP CURVE
A positive displacement (PD) pump produces the same flow at a given speed (in revolutions per minute--RPM) no matter what the discharge pressure. Positive displacement pump curves give you the information you need to determine a pump's ability to produce flow under the conditions that affect pump performance.
PD pumps come in a variety of mechanical designs, to name a few:
A?Positive Displacement Pump Curve?answers several important questions during the pump selection process:
Curves answer those questions by displaying intersections of several important variables, including capacity, work horsepower, viscous horsepower, and Net Positive Suction Head required (NPSHr).
CAPACITY
Capacity, as illustrated in the curve below, is the volume of fluid a pump can displace by RPM.
领英推荐
As RPM increases, the pump flow increases, from 0 gallons per minute or (GPM) at 0 RPM, to about 130 GPM at 500 RPM. Remember that some performance curve calculators might include units such as liters per minute (LPM), so check calculation units when using calculators.
A?PD pump?curve indicates pump capacity, on the horizontal lines, in units per minute. In this example, the curve indicates?gallons per minute (GPM)?and?liters per minute (LPM)?in the left margin and the vertical lines indicates pump speed in?revolutions per minute (RPM).
THE IMPORTANCE OF VISCOSITY IN PUMP SELECTION
Positive displacement pumps deliver a constant flow of fluid at a given pump speed. When viscosity increases, however, resistance to flow increases, so to maintain system flow at higher viscosities, pumps require more horsepower.
Low viscosity also affects pump performance in the form of slip.?Slip is the internal recirculation of low viscosity fluid from the discharge side of the pump back to the suction side of the pump.?The amount of slip in a PD pump is influenced by the fluid’s viscosity and the?discharge pressure.
As discharge pressure increases, keeping viscosity constant,?more fluid slips from the discharge side to the suction side of the pump, so the pump must spin at a higher RPM to maintain output.
In the curve below, a positive displacement pump curve shows the influence of viscosity on slip with a correction chart. With changes in viscosity and pressure, slip correction indicates that flow capacity drops from a high of about 7 GPM to a low of about 3.5 GPM. Once viscosity is over 1000 cPs, slip basically doesn’t occur in liquid sanitary pumps.?If slip is not a factor, use the 0 PSI line to determine flow rate.
Because PD pumps generate flow to transport relatively high viscosity fluids, PD pump selection requires analysis of three key influences on fluid transfer:
The fluid’s?dynamic viscosity, density,?and response to?shear.
Slip correction accounts for variations in pump performance while factoring fluid viscosity (resistance to flow) and discharge pressure.
DYNAMIC VISCOSITY
Dynamic viscosity is a measure of a fluid’s resistance to flow.?By common sense alone, we can imagine that water is less viscous, or resistant to flow, than corn syrup, so corn syrup has a higher viscosity than water. We measure internal resistance to flow as absolute viscosity (also referred to as dynamic viscosity). It is critical for the viscosity used to be consistent with “in pump” shear conditions, or shear rates of 800 or more s-1 (inverse seconds). As the following comparison shows, differences in viscosity vary dramatically by fluid:
DENSITY
Density is a measure of a fluid’s weight by volume.?Water is less dense than corn syrup, for example, so if you put equal volumes of water and corn syrup side by side, the corn syrup would weigh more than the water. Also, due to the differences in density between water and corn syrup, water would float on top of the corn syrup if combined. The following comparison shows the difference in density between water and corn syrup in kilograms per cubic meter:
SHEAR
Shear-sensitive liquids?change viscosity when under stress,?such as when they are hit by an impeller inside a pump. Some liquids become less viscous with increased force (called shear thinning), while others become more viscous with increased force (called shear thickening).?
By comparison,?Newtonian liquids, such as water, do not change their viscosity, regardless of shear.
The viscosity of shear-sensitive substances through a process line does change, however. Common shear-sensitive substances include ketchup, shampoos, and polymers; as shear increases during ketchup processing, ketchup’s viscosity decreases.
Continuing with the ketchup processing example, the next section discusses additional important information on pump curves:?work horsepower (WHP), viscous horsepower (VHP), and Net Positive Suction Head required (NPSHr).
BRAKE HORSEPOWER
When you size a PD pump it will be important to select the correct brake horsepower.?Brake horsepower (BHP)?is the power the pump requires to overcome the discharge pressure. BHP is determined by adding the work horsepower (WHP) and the viscous (VHP) horsepower.
BHP = WHP + VHP
To properly analyze brake horsepower, you must look at work horsepower versus viscous horsepower.
WORK HORSEPOWER
Work horsepower (WHP) is the horsepower required for the selected PD pump to achieve the desired flow rate considering the anticipated pressure drop from system components.?Components like valves,?heat exchangers, and?filter/strainers, to name a few. WHP is sometimes called external horsepower.
To determine WHP find the intersection of anticipated differential pressure (PSI) and RPM, as shown in the curve below. Recall the required RPM was a result of flow required coupled with slip correction, if any.
Work horsepower (WHP), is the horsepower required to operate a Positive Displacement Pump. As pressure from the discharge side of the pump increases, the pump requires additional horsepower to operate. For example, at 300 RPM and with 150 PSI, the pump requires 6.7 working horsepower.
VISCOUS HORSEPOWER
Maintaining pump capacity at various viscosities requires meeting horsepower minimums, as shown in the curve below. There is a certain minimum horsepower requirement to force the rotating parts of the pump to turn, considering the viscosity of the fluid in the pump.?VHP is sometimes called internal horsepower.
To arrive at required horsepower for an application, add WHP and VHP.
Viscous Horsepower (VHP) is the power needed to turn rotating parts of the pump against the fluid inside the pump. At 300 RPM and a viscosity of 500 CPS, a pump requires 4 VHP.
You will find additional information about pumps on these CSI pages:
For the complete line of CSI centrifugal pumps and?pump repair?services, visit?CSI?today.
NEXT STEPS
As you processor, you need a pump that transfers product safely and efficiently from point A to point B. But with such a large variety of pumps, motors, and applications, picking the right pump can be difficult.
That's where we come in!
CSI is known as the experts in the specification, sizing, and supplying of pumping technology for hygienic industry processes. Speak with our knowledgeable pump team today and be confident in your next pump purchase!
ABOUT CSI
Central States Industrial Equipment (CSI) is a leader in distribution of?hygienic pipe,?valves,?fittings,?pumps,?heat exchangers, and MRO supplies for hygienic industrial processors, with four distribution facilities across the U.S. CSI also provides detail design and execution for hygienic process systems in the food, dairy, beverage, pharmaceutical, biotechnology, and personal care industries. Specializing in process piping, system start-ups, and cleaning systems, CSI leverages technology, intellectual property, and industry expertise to deliver solutions to processing problems. More information can be found at?www.csidesigns.com.