GAS AUTO TENSIONING DEVICES

GAS AUTO TENSIONING DEVICES


THE GAS AUTO TENSIONING DEVICES CONSISTS OF THE FOLLOWING:-

No alt text provided for this image

A cylinder assembly, with a movable ram.

Cable tie-bar.

OHE end Cross head.

Mast side Cross head.

GAS AUTO TENSIONING DEVICES

1.Utilises Perfect GAS Principal

2.Matches Expansion Rate of GAS to that effective Contact wire length

3.Tension proportional to Gas charging Pressure.

Unlike the pulley-block type ATD’s, the Gas Tensioner does not require the use of any counter weights.

The expansion/contraction of the OHE (due to temperature variation) is transmitted to the movable ram, via the cable tie-rod.

The ram moves against pre-set pressure of Nitrogen gas inside the cylinder and thereby maintains the tensions in the overhead traction wires to the pre-determined values.

The maximum horizontal travel (stroke) of the ram will depend upon the tension length and the maximum variation in temperature.

Different models are available depending upon the maximum available stroke. Generally, the maximum available strokes are 500 mm, 900 mm, and 1250 mm.

                                                            TECHNICAL DATA

No alt text provided for this image
No alt text provided for this image
No alt text provided for this image

DISADVANTAGES OF GAS AUTO TENSIONING DEVICES

The main disadvantage in the case of Gas Tensioners is that their use is still not very extensive and hence the source of supply is very limited. As a consequence, the price of Gas Tensioner is, at the moment, very high, almost 4-5 times that of conventional ATD.

Another disadvantage of the Gas Tensioner is that for every Gas Tensioner, the values of installed pressure and ram-extension, have to be calculated taking into account the tension length of the OHE, where the particular Gas Tensioner is to be installed. This puts a severe restriction on interchangeability between different Gas Tensioners, which disadvantage does not exist in the case of conventional ATD’s.

RECOMMENDATIONS :

Particularly Gas ATD useful in long tunnels & elevated sections. However, its use may be resorted to only in exceptional cases, since its cost is high. 


Matthew Hack

Not currently employed

1 年

Thanks for posting this Anubhav. Our light rail system, the West Midlands Metro, uses gas tensioners extensively. They are great as long as they work. We are having difficulty obtaining support for them as they are no longer available in the UK. I'd be extremely grateful if you could let me know of any organisation in India that can overhaul or supply new units.

回复
Varun Gupta

|| Sr Manager|| B.TECH || MBA || ISO 9001:2015 || NDT || CAD || TBM Engineer ||

3 年

Thanks for posting ??

回复
Dipak Prajapati

Regional Head-Quality at KEC| 14+ Years into Quality Leader| Quality 4.0 | Lean Six Sigma Black Belt| CII, CQI & IRCA Certified Quality Professional | Lead Auditor | Trainer | Mentor

3 年

Great Article Anubhav kumar Jain....Keep posting on various advanced technology in Railways.