Fire Stopping Various Service Penetrations through Core Holes in BARE Xlam Cross Laminated Timber Floors

Fire Stopping Various Service Penetrations through Core Holes in BARE Xlam Cross Laminated Timber Floors

As a Result of our Comprehensive AS1530.4-2014 Fire Testing Program 2022.

TBA Firefly? are pleased to announce that we can now provide Fire Stopping Solutions for the Cross Laminated Timber Industry to retain the natural look of their CLT without the requirement to cover it up with Fire Grade Plasterboard.

TBA Firefly? Solutions which meet Full DTS Compliance with the NCC.


No alt text provided for this image

TBA Firefly? Systems must be Designed/Installed/Signed Off in Strict Accordance with the concise construction details contained within the following Compliance Report and ID No’s for the Specific Application and FRL achieved.

Over 46 TBA Firefly? FRL-/90/90 Systems protecting Electrical, Communications, Mechanical, Fire & Security, Plumbing & Hydraulic & Wet Fire, service Penetrations passing through Core Holes in XLAM 90 Minute Bare CLT 130mm thick Floor System.

Over 46 TBA Firefly? FRL-/60/60 Systems protecting Electrical, Communications, Mechanical, Fire & Security, Plumbing & Hydraulic & Wet Fire service Penetrations passing through Core Holes in XLAM 60 Minute Bare CLT 130mm thick Floor System.

All Tested in accordance with AS1530.4-2014 and Assessed in accordance with AS4072.1-2005 and confirmed in Reports from an Accredited Testing Laboratory.

Warringtonfire Report No: FAS190236 RIR Specific ID No's: H121 through to H140

This Report is from an Accredited Testing Laboratory which meets Specification A2.3 Section 2 (c) of NCC2016 Amendment 1 (Including Prior Versions) & Schedule 5 Section 2 (c) of NCC2019 (Including Amendment 1) & Specification 1, S1C2 Part (c) (i) & (ii) of NCC 2022 (Preview) for determination of an FRL.

No alt text provided for this image
No alt text provided for this image
No alt text provided for this image

For more details, please click on the link below:

https://www.tbafirefly.com.au/mass-timber-construction-passive-fire-protection/bare-cross-laminated-timber-floors-fire-stopping-service-penetrations-through-core-holes

Trevor Kempster

Passive Fire Protection Creator & Compliance Consultant TKCS

2 年
回复
Trevor Kempster

Passive Fire Protection Creator & Compliance Consultant TKCS

2 年
回复
Trevor Kempster

Passive Fire Protection Creator & Compliance Consultant TKCS

2 年

Farell Saldanha

回复

要查看或添加评论,请登录

FIREFLY AU的更多文章

社区洞察

其他会员也浏览了