Fan cooling battery pack
The purpose of this document is to describe the specifications of the air-cooled battery boxand toprovide customers with information on the use of this product.The standard delivery of this product is the battery box. It does not include the installation screws of the air-cooled battery box, the external positive and negative cables,External communication line (BMU communication interface),external fanpower supply harness. Refer to the table below for a detailed list of components.
1.Nominal voltage: 48V
2.Nominal Power: 13.4kWh 0.5P @25±3℃
3.Configuration: 1P15S by LF280K cells .
4.Working temperature : charge-0℃~55℃ ,discharge--20℃~55℃
5.Communication method : CAN
6.Size: W510×D647×H240mm
7.Weight: 100kg±5kg
Fan cooling batterypack configuration of15pcs LF280Kcells by 1P15S,inner integration of 1pc BMU,2pcs DC axial fan and other components.
If you want to know more information , please contact us :