With the continuous advancements in energy storage technology and the decreasing prices of lithium batteries, the cost of battery energy storage systems?(ESS)?is gradually decreasing, which?highlights the increasing economic viability of battery energy storage applications in the commercial and industrial (C&I) sectors.. According to relevant data, the annual average growth rate of global C&I?energy storage from 2021 to 2023 reached 169%.
As one of the major consumers of energy, industrial parks often face the burden of high electricity costs. Additionally, they can suffer significant losses during power outages caused by grid overloads or other failures. In recent years, under the global consensus on "carbon reduction," many countries and regions have increasingly deployed renewable energy in their industrial parks. For example, solar panels are installed on rooftops or on the ground to generate power for park use. However, the power generation from these renewable sources is susceptible to seasonal and weather variations, resulting in volatility and uncertainty. This prevents renewable energy from reliably and consistently replacing traditional energy sources in providing a stable power supply to industrial parks.
Next, this article will discuss one of the typical application scenarios for C&I?energy storage: Industrial Parks + Energy Storage.
Q
What is Industrial Park + Energy Storage?
A
As literally understood, Industrial Park + Energy Storage refers to deploying such energy systems within traditional industrial parks to address their specific energy needs and challenges. Traditional industrial parks typically feature a large number of equipment characterized by high power consumption, prolonged periods of high-load operation, and high energy consumption. Implementing ESS?can help industrial parks balance electricity supply and demand, effectively manage energy fluctuations and peak-demand variations, ensure stable power supply, and optimize energy utilization efficiency.
Q
What are the prerequisites for configuring energy storage in industrial parks?
A
Q
What are the advantages of building ESS in industrial parks?
A
Storing electricity during off-peak periods when prices are low and utilizing stored electricity during peak periods when prices are high, the peak-load shifting?can significantly reduce electricity costs for industrial park enterprises.
(1)Reduce Grid Pressure: Alleviating peak electricity demand during high-load periods within industrial parks, especially during daytime peaks for manufacturing enterprises. ESS?can provide electricity during peak demand, reducing reliance on the grid and helping balance grid loads.?
(2)Emergency Backup Power: During grid failures or power outages, ESS?can serve as emergency power sources, ensuring continuous operation of critical equipment and systems in industrial parks.
(1)Optimize Energy Use: For industrial parks equipped with renewable energy,?ESS?can store surplus electricity generated from renewable sources such as solar and wind within industrial parks, smoothing power output and reducing waste,?maximizing the utilization of renewable energy .
(2)Reduce Carbon Footprint: By increasing the efficiency of renewable energy utilization, industrial parks can reduce?reliance on traditional fossil fuels?and decrease their carbon emissions, promoting sustainable development.
(1)Capacity Management: ESS capacity management refers to the systematic planning, allocation, scheduling, and optimization of the system's capacity using scientific methods and technological tools. The goal is to ensure the system efficiently meets electricity demand while maximizing effectiveness and benefits. This involves utilizing historical electricity usage data and operational data from the storage system to analyze trends in electricity load and storage demand. By doing so, the capacity configuration and scheduling strategies of the storage system can be optimized.
Capacity management for energy storage must be tailored to specific scenarios and requirements. For instance, in industrial park ESS, capacity management can help enterprises reduce grid electricity purchases during peak pricing periods, thus lowering electricity costs. In photovoltaic (PV) + ESS, capacity management can optimize the coordination between PV generation and storage batteries, increasing self-consumption rates and overall system efficiency.
(2)Deferring Grid Expansion Needs: ESS can provide power support for certain loads during peak demand periods, thereby delaying or avoiding the need for investments in expanding transmission and distribution infrastructure.
(1)Quick Return on Investment: ESS?can deliver significant economic benefits through electricity cost savings, arbitrage from the TOU?Tariff?and optimized energy management, achieving a quick return on investment.
(2)Diversified Revenue Streams: Industrial parks can generate additional income by participating in grid ancillary services such as frequency regulation and voltage support, further enhancing the economic benefits of ESS.
(1)Green Brand Image: Adopting renewable energy + ESS?enhances a industrial park’s or company's green image, aligning with societal expectations for environmental conservation and sustainable development, thereby strengthening market competitiveness.
(2)Policy Support: Government support policies and subsidies for green energy and energy storage projects further promote the application and development of ESS?in industrial parks?and help to enhance the reputation and competitiveness of such businesses.
To sum up, by implementing ESS?in industrial parks, cost savings, improved power quality and stability, optimized energy utilization, enhanced economic benefits, and business competitiveness can be achieved, fostering sustainable development within industrial parks.
Q
What should I pay attention to when installing an ESS in an industrial park?
A
When installing ESS in industrial parks, the following aspects need to be paid attention to:
领英推荐
(1)Demand Assessment: Accurately assess the electricity demand and load characteristics of the industrial park to determine the capacity and configuration of the ESS.
(2)Compatibility: Ensure compatibility of the ESS?with existing electrical infrastructure and equipment to avoid unnecessary electricity waste or equipment damage.
(1)Battery Safety: Select batteries?with high safety performance and install?& conduct?safety measures such as fire prevention and explosion protection.
(2)Safety Standards: Adhere to relevant electrical and safety standards to ensure the installation and operation of the ESS?comply with national or local safety regulations.
(1)Cost-Benefit Analysis: Conduct detailed economic analysis including initial investment, operational maintenance costs, and expected returns to ensure the investment return rate of the ESS.
(2)Subsidy Policies: Understand and utilize government subsidies and incentives to lower investment costs.
(1)Efficient Equipment: Select efficient and stable energy storage equipment to ensure long-term system operation.
(2)Smart Management: Equip with intelligent energy management systems to enhance operational efficiency and automation of the ESS.
(1)Installation Environment: Choose suitable installation locations to ensure the ESS?operates under optimal environmental conditions, mitigating impacts from extreme weather or environmental factors.
(2)Space Planning: Properly plan the installation space for the ESS?to facilitate ventilation, heat dissipation, and ease of maintenance.
(1)Maintenance Plan: Develop detailed maintenance plans and emergency response procedures to ensure the ESS?can quickly resume normal operation in case of faults or emergencies.
(2)Monitoring System: Install real-time monitoring systems to promptly detect and address operational issues of the ESS, ensuring system stability.
(1)Compliance: Ensure that the design, installation, and operation of the ESS?comply with local laws, regulations, and policy requirements.
(2)Policy Updates: Stay informed about policy changes and adjust operational strategies of the ESS?to maximize policy incentives.
By adhering to these considerations, ensure that the installed ESS?in industrial parks operates safely, efficiently, and economically, effectively fulfilling its role in peak-load shifting, backup power,?energy conservation?and consumption reduction, and grid stabilization.
Vilion Industrial Park + energy storage project case
Specific application:The ESS supplied by?Vilion?for an industrial park in Shanxi Province is mainly worked in parallel by 6 sets of EnerArk cabinets, which?well meets the application of power expansion and peak-load shifting in the industrial park and ensure stable power supply and normal production & operation. Besides, the industrial park can get benefit from the electricity price difference and finally realize the comprehensive reduction of enterprise electricity costs.
Specific application: BESS provides power frequency modulation and auxiliary services for the food factory, ensuring the safe and stable operation of the power system.
Specific application:The solar + battery energy storage system stores excess solar energy for nighttime use. The BESS will make full use of the TOU tariff policy, purchase electricity from the utility grid for storage in the valley price section, discharge power during the peak price period, and supply the loads of enterprises, so as to earn profit from the peak-valley price difference and reduce the electricity cost.
Specific application:The 12set?ESS supplied by?Vilion?for an industrial park in Guangdong is mainly used in power peak-load shifting, and helps the industrial park to effectively reduce electricity cost and improve power quality by the?ESS discharging?at peak time,?charging at?normal and?valley?time of?the?electricity?price, so as to ensure the industrial park to achieve stable, safe and reliable electricity consumption?with the?low cost.
Specific application:The energy storage cabinet is applied in an industrial park in Longgang district, Shenzhen. As a demonstration project of energy storage + charging station, it helps the industrial park achieve peak-load shifting. The electricity demand curve can be effectively adjusted through the charging and discharging process of the battery energy storage cabinet. In the low period of electricity price, the utility grid will charge to the battery energy storage cabinet. In the peak period of electricity price, the battery energy storage cabinet will provide power to the electric vehicles in the industrial park, so as to achieve the goals of energy transfer and obtain revenue from the difference of electricity bills of different periods, and accomplish the goal of comprehensively reducing the power consumption cost.
Specific application: An industrial park in Zhejiang region is densely populated with factories and the load on the power grid has increased greatly. Traditional transformers can no longer meet the power demand, so dynamic expansion of transformers is required to ease the pressure on the power grid. The outdoor battery storage cabinet supplied by Vilion can provide additional power to the grid when needed. In combination with an ESS,the load pressure on the transformer can be reduced, thus postponing or avoiding the need for the transformer's capacity expansion.