Do windows 4 & 5 require fire-rating?

Do windows 4 & 5 require fire-rating?

Does windows W04 & W05 in this particular scenario need to be fire rated?


Question:

I have received the following question, and I thought I share this with you.

The Study room windows are outside 900 mm. However, the wall is within 900 mm.

In your opinion, does the window need to be fire rated in this case?

> Do you agree with my response below? Please advise if I have skipped anything.


My response:

Assuming this is for Class 1a dwelling.

The quick answer is: No, windows (W04 & W05) do NOT need to be fire rated in this instance.

According to the following:

  • 3.7.2.1 (a) ; and
  • 3.7.2.3 (a) ; and
  • 3.7.2.3 9(b) ; and
  • Figure 3.7.2.2a

Any walls that are not parallel to site boundary line (Including any openings within them) do not need to be fire rated. So long as they are not less than 900 mm from any site boundary.

See highlighted below.??

No alt text provided for this image
No alt text provided for this image

However. I have the following note to make here:

According to Figure 3.7.2.1 below, any walls that are located at right angels or more from the boundary are not required to be fire rated.

No alt text provided for this image

It states the following:

“No protection required for the wall at right angles or more to the boundary.” Notice it says “at right angles or more to the boundary” in this particular scenario, they are located at less than right angle or < 90 degrees to the boundary. Would that exemption still apply in your opinon?

MIND YOU: There is a trick here. ?? I think the answer is in this diagram below: ?Figure 3.7.2.2a.

No alt text provided for this image


Please accept my apology if this was below your high standard and sophisticated professional level. But, this article was targeted towards new Building Surveyors, Architects, Building Designers, or Builders who are just entering the field. ?

If you find this post is interesting, give us a thumbs up. ??


Regards

Firas Naji

29 September 2022

Ha NGUYEN

Expertise in Architectural Design/ Drafting and Compliance for residential house (duplex, single dwelling, granny flat..)

2 年

Thanks for sharing information Firas. Really useful information as I have been having mixed feed back regarding fire rating for wall “not parallel” to side boundary.

FADI HABBOUCHE

Principal Certifier at Certify Right! Pursuing my passion and making a difference.??

2 年

Well said and explained

要查看或添加评论,请登录

Firas Naji的更多文章

社区洞察

其他会员也浏览了