Do windows 4 & 5 require fire-rating?
Firas Naji
Senior Building Surveyor - Fire Safety (Grade A1 Unrestricted All Classes of Building) @ Campbelltown City Council | Town Planner & Building Code (BCA) Consultant @ Silver End Pty Ltd
Does windows W04 & W05 in this particular scenario need to be fire rated?
Question:
I have received the following question, and I thought I share this with you.
The Study room windows are outside 900 mm. However, the wall is within 900 mm.
In your opinion, does the window need to be fire rated in this case?
> Do you agree with my response below? Please advise if I have skipped anything.
My response:
Assuming this is for Class 1a dwelling.
The quick answer is: No, windows (W04 & W05) do NOT need to be fire rated in this instance.
According to the following:
Any walls that are not parallel to site boundary line (Including any openings within them) do not need to be fire rated. So long as they are not less than 900 mm from any site boundary.
See highlighted below.??
领英推荐
However. I have the following note to make here:
According to Figure 3.7.2.1 below, any walls that are located at right angels or more from the boundary are not required to be fire rated.
It states the following:
“No protection required for the wall at right angles or more to the boundary.” Notice it says “at right angles or more to the boundary” in this particular scenario, they are located at less than right angle or < 90 degrees to the boundary. Would that exemption still apply in your opinon?
MIND YOU: There is a trick here. ?? I think the answer is in this diagram below: ?Figure 3.7.2.2a.
Please accept my apology if this was below your high standard and sophisticated professional level. But, this article was targeted towards new Building Surveyors, Architects, Building Designers, or Builders who are just entering the field. ?
If you find this post is interesting, give us a thumbs up. ??
Regards
Firas Naji
29 September 2022
Expertise in Architectural Design/ Drafting and Compliance for residential house (duplex, single dwelling, granny flat..)
2 年Thanks for sharing information Firas. Really useful information as I have been having mixed feed back regarding fire rating for wall “not parallel” to side boundary.
Principal Certifier at Certify Right! Pursuing my passion and making a difference.??
2 年Well said and explained