Dewing test according to GS 95011-4 (K-15 of LV 124)
WHY – The challenge.
Motor vehicles are exposed to a wide variety of climates, which inevitably results in condensation on electrical assemblies - this can lead to malfunctions when the vehicle is running. The GS 95011-4 standard (also known as K-15 of LV 124 or 宝马 Condensation Test) describes the sequence of a condensation procedure used to test electronic assemblies used in motor vehicles. The purpose of this test is to identify any functional deficiencies of the assembly subjected to condensation during the development phase of assemblies.
WHAT – The Test
领英推荐
The dewing test can only be carried out in a climate test chamber equipped with a dewing option. The temperature control of the climate test chamber is switched from test space to water bath during the dewing phase (see Figure 2). Water should deposit on the cold test specimen. If dewing of the assembly occurs frequently this can result in electrochemical migration (dendritic growth). This in turn leads to permanent damage or failure of the assembly. The test specimen must be dry between each cycle. The standard specifies that in point 2) the humidity must be <50% RH (see Figure 2). In addition, contamination should become concentrated with each cycle. Therefore, this should happen in 5 cycles in a row. In order to achieve the desired dewing result with this procedure, the climate test chamber used must produce temperature differences between the inside wall of the test space and the test space which are smaller than the temperature difference in temperature between the test specimen and the testing temperature. The difference between water bath and test space temperature must be <15 K. (GS 95011-4, 2010)
HOW – The Solution.
The new climate test chambers ClimeEvent from weisstechnik are prepared for carrying out the dewing test according to GS 95011-4. A water bath sensor is installed by default to control the water bath temperature during the dewing phase. With the new ClimeEvent, even the critical part in the drying phase, marked with a red circle in Fehler! Verweisquelle konnte nicht gefunden werden., is no problem, since the appropriate dehumidification capacity is installed to achieve a humidity value <50% RH. To carry out GS 95011-4, all that is required is the plastic hood shown on Figure1 and the test in the test field required by the standard including recording of the test run in the control software*. Further information you’ll find in the test run with a new ClimeEvent below (see Fehler! Verweisquelle konnte nicht gefunden werden.).
Dewing test according to GS 95011-4_2010-06 (K-15 of LV 124)
Want to know more? Join our Deep Dive Webinar with Expert Ralph Theiss next week: https://bit.ly/3IYdmcO