Connection group in transformers
Connection group in transformers - POLYLUX

Connection group in transformers

The connection group for a three-phase electrical transformer refers to the specific arrangement of the primary and secondary windings of the transformer. It defines how windings are connected to form a particular configuration and is essential to ensure the correct voltage and phase ratios between input and output.

The choice depends on the specific application, voltage requirements, and electrical system design. Different countries and regions may have their own standards and preferences for transformer connection groups, so local practices should also be considered.

?

Common applications and connection groups as follows:

a-???? Yy or Y-Y: this configuration connects the primary and secondary windings in a "Y" or "star" configuration. It is characterized by a neutral point in both the primary and secondary windings.

  • Distribution transformers
  • Grounding
  • Low-voltage systems

b-???? Dd or Δ-Δ: in this configuration, the primary and secondary windings are connected in a "delta" configuration. There is no neutral point in this arrangement.

  • Isolation transformers
  • Industrial applications
  • Specific voltage ratios

c-???? Yd or Y-Δ: this arrangement connects the primary winding in a "Y" configuration and the secondary winding in a "delta" configuration.

  • Phase splitting
  • Neutral current reduction
  • Transformer taps

d-????? Dy or Δ-Y: connects the primary winding in a "delta" configuration and the secondary winding in a "Y" configuration.

Voltage transformation

Load balancing

Harmonic reduction

e-???? The "Z" connection group: is a specialized transformer connection that is primarily used for applications where a balanced two-phase supply from a three-phase source is required. It's not as commonly used as other connection groups like Yy or Dy, but it has specific applications:

Two-phase systems

Load balancing

Reduced harmonics:

It is important to note that the Z connection is relatively less common and is mainly used in specialized industrial applications where a balanced two-phase supply is necessary.

?

Here are some examples of common connections:

Common connections examples - POLYLUX

The "angle" of a connection group refers to the relative phase change between the primary and secondary windings of the transformer. It is an important feature that defines how windings are connected to create specific voltage and phase relationships between the input and output sides of the transformer.

The angle of the connection group is usually expressed in degrees.


Some examples:

  • 0° Phase Shift: in this configuration, the primary and secondary voltages are in phase, meaning they peak and trough at the same time. This is known as a "zero-phase" or "in-phase" offset connection (such as 0 in Yyn0).
  • 30° Phase Shift: this setting shifts the secondary voltage 30 degrees relative to the primary voltage (such as 1 in Dy1).
  • 150-degree phase shift (150° or 5x30°): this setting shifts the secondary voltage 150 degrees relative to the primary voltage (such as 5 in Dyn5).?

At POLYLUX, in order to be able to offer a solution adapted to the needs of our customers and the requirements of their electrical projects, we can manufacture transformers on request with the connection groups that are necessary depending on the application.


For more information, please download our document on transformer connection groups:

Connection group in transformers - POLYLUX

DOWNLOAD DOCUMENT