"COMMON CHALLENGES IN AIR RECEIVERS AND EFFECTIVE SOLUTIONS"

"COMMON CHALLENGES IN AIR RECEIVERS AND EFFECTIVE SOLUTIONS"

"COMMON CHALLENGES IN AIR RECEIVERS AND EFFECTIVE SOLUTIONS"

  1. Defective safety valve?– Air receivers?are designed?to operate within specific?parameters. A defective safety valve can result in the over-pressurisation and the potential for significant damage to the air receiver and injury to those in its vicinity.

????? I.??????? Inspect the safety valve regularly for any signs of wear, corrosion, or malfunction.

??? II.??????? Ensure that the safety valve is appropriately sized for the air receiver.

?? III.??????? Conduct routine testing to verify the proper functioning of the safety valve.

? IV.??????? Replace the safety valve if any defects are identified during inspections.

  1. High levels of condensate inside air receivers?– Air receivers should be drained of water daily. Any build-up of water could cause?condensate to travel down the air lines and damage technicians air tools. The compressor will operate more frequently causing the compressor and motor to overheat.?All of which are expensive situations that can be easily avoided.

????? I.??????? Implement an effective condensate drainage system by installing automatic drains.

??? II.??????? Ensure that the air receiver is positioned and leveled to facilitate proper condensate drainage.

?? III.??????? Periodically check and clean the condensate drains to prevent clogs.

? IV.??????? Install moisture traps upstream of the air receiver to reduce condensate entering the system.

  1. Blocked blow down / drain valve?– This will prevent the air receiver from being blown down daily?as required. The results could be a?build-up of water causing condensate to travel down the air lines and damage technicians air tools and overheating of the compressor and motor. Again, expensive situations that can be easily avoided.

????? I.??????? Regularly inspect and clean the blow down/drain valve to prevent blockages.

??? II.??????? Install a filter upstream of the blow down valve to catch debris and contaminants.

?? III.??????? Implement a scheduled maintenance routine for cleaning and testing the blow down/drain valve.

? IV.??????? Train personnel on proper maintenance procedures and the importance of keeping the valve clear.

  1. High levels of emulsified oil inside the air receiver?– As with high levels of condensate this potentially could be very expensive. The emulsified oil build up could also be identifying that there is excessive wear taking place within the compressor. Easily remedied if caught early.

????? I.??????? Install effective oil separation filters in the compressed air system.

??? II.??????? Regularly monitor and replace filters to prevent oil carryover.

?? III.??????? Conduct regular checks on the air compressor for any oil leakage.

? IV.??????? Implement routine oil analysis to detect and address potential issues early.

  1. No clear indication of the safe working pressure marked on the air receiver?– This has to be marked on the air receiver to aid the operators, service technicians and inspection engineer during the course of their duties.

????? I.??????? Ensure that the air receiver is clearly marked with the designated safe working pressure.

??? II.??????? Conduct regular inspections to verify the visibility and accuracy of pressure markings.

?? III.??????? If markings are unclear or missing, repaint or reapply them using durable and visible materials.

? IV.??????? Educate personnel on the importance of adhering to the specified safe working pressure.

?