Can globe valves and gate valves be mixed?

Can globe valves and gate valves be mixed?

Structurally

No alt text provided for this image

               

When the installation space is limited, please pay attention to the selection:


The gate valve can be tightly closed with the sealing surface depending on the medium pressure, so as to achieve the effect of no leakage. When opening and closing, the valve core and the valve seat sealing surface are always in contact and rub against each other, so the sealing surface is easy to wear. When the gate valve is close to closing, the pressure difference between the front and back of the pipeline is large, which makes the sealing surface wear more serious.

                 

The structure of the gate valve will be more complicated than the globe valve. From the appearance point of view, the gate valve is taller than the globe valve and the globe valve is longer than the gate valve in the same caliber. In addition, the gate valve can be divided into bright rod and dark rod. The globe valve does not.


working principle

No alt text provided for this image


When the globe valve is opened and closed, the stem rises, that is to say, when the hand wheel is turned, the hand wheel will rotate and lift together with the stem. The gate valve rotates the hand wheel to make the valve stem move up and down, and the position of the hand wheel remains unchanged.


The flow rate is different, the gate valve is required to be fully open or fully closed, but the stop valve is not required. The globe valve has specified inlet and outlet directions, and the gate valve has no inlet and outlet direction requirements.


In addition, the gate valve has only two states: fully open or fully closed, the gate opening and closing stroke is large, and the opening and closing time is long. The movement stroke of the valve plate of the globe valve is much smaller, and the valve plate of the globe valve can be stopped at a certain place during the movement for flow adjustment. The gate valve can only be used as a cut-off and has no other functions.

No alt text provided for this image


Performance difference


The globe valve can be used for cut-off and flow adjustment. The fluid resistance of the globe valve is relatively large, and it is more laborious to open and close, but because the distance between the valve plate and the sealing surface is short, the opening and closing stroke is short.


Because the gate valve can only be fully opened and fully closed, when it is fully opened, the flow resistance of the medium in the valve body channel is almost zero, so the opening and closing of the gate valve will be very labor-saving, but the gate is far away from the sealing surface and the opening and closing time is long .


Installation and flow


The effect of the gate valve in both directions is the same. There is no requirement for the inlet and outlet directions for installation, and the medium can flow in both directions. The stop valve needs to be installed in strict accordance with the direction indicated by the arrow on the valve body. There is also a clear provision about the import and export direction of the stop valve. my country's valve "three chemical feed" stipulates that the flow direction of the stop valve should be from top to bottom.


The globe valve is low in and high out. From the outside, it is obvious that the pipeline is not on the horizontal line of one phase. The gate valve flow path is on a horizontal line. The stroke of the gate valve is larger than that of the stop valve.


From the perspective of flow resistance, the flow resistance of the gate valve is small when fully opened, and the flow resistance of the load stop valve is large. The flow resistance coefficient of ordinary gate valve is about 0.08~0.12, the opening and closing force is small, and the medium can flow in two directions. The flow resistance of ordinary globe valves is 3-5 times that of gate valves. When opening and closing, it needs to be forced to close to achieve the seal. The valve core of the stop valve does not contact the sealing surface when it is completely closed, so the wear of the sealing surface is very small. Because the main force of the flow is large, the stop valve that needs an actuator should pay attention to the torque control mechanism Adjustment.


There are two ways to install the globe valve. One is that the medium can enter from below the valve core. The advantage is that the packing is not stressed when the valve is closed, which can prolong the service life of the packing and can bear pressure before the valve. Under the circumstance, the packing should be replaced; the disadvantage is that the driving torque of the valve is relatively large, which is about 1 times that of the upper flow, the axial force on the valve stem is large, and the valve stem is easy to bend.


Therefore, this method is generally only suitable for small-diameter stop valves (below DN50). For stop valves above DN200, the medium flows in from above. (The electric globe valve generally adopts the way that the medium enters from above.) The shortcoming of the medium entering method from above is just the opposite of the method of entering below.

No alt text provided for this image


Sealed


The sealing surface of the globe valve is a small trapezoidal side of the valve core (see the shape of the valve core for details). Once the valve core falls off, it is equivalent to closing the valve (if the pressure difference is large, of course the closing is not tight, but the anti-reverse effect is not bad). The gate valve is sealed by the side of the valve core gate plate, the sealing effect is not as good as the stop valve, and the valve core will not be closed like the stop valve when the valve core falls off.