Adding Hydraulic Fluid to the Reservoir

Adding Hydraulic Fluid to the Reservoir

No alt text provided for this image

Adding make-up fluid to the reservoir ranks among the most important maintenance tasks because of the consequences of doing it incorrectly. Be aware that a system that needs make-up fluid on a regular basis has a leak. Discovering the source of that leak and fixing it is necessary to keep the system operating properly.

Keeping the fluid at the proper level is important. A system that is overfilled when it is cold will spill out fluid through the vent breather when the system warms up because the fluid will expand.

A system that becomes low on fluid can cause the pump to whine and aerate the fluid. On mobile hydraulic systems that have limited capacity reservoirs, a low fluid level may not cause the pump to whine and aerate the fluid, but will overheat the system because of insufficient cooling. Remember that the capacity of the reservoir may be no more than the gallon per minute flow rating of the pump to begin with, and reducing that capacity with a low fluid level will cause the same fluid to be circulated more frequently through the system where it will pick up additional heat before it has cooled sufficiently.

If the pump is mounted below the reservoir, fluid normally floods the inlet to the pump. If pump noise indicates the pump is aerating, the system is out of fluid and must be stopped immediately to prevent the pump from being burned up. Pumps that are mounted above the reservoir will allow the ingression of air into the fluid as the level drops below the inlet. This allows air to enter the pump with the fluid, circulate through the system, and to aerate fluid in the reservoir. In addition to the tell-tale whine of the pump and foam in the reservoir, operation of cylinders will become spongy and jerky. Continued operation of the system is both dangerous to personnel and will damage the pump.

The fluid level on a machine is normally checked at operating temperature, either with a sight gage or a dip stick. Do not fill the machine to the full mark when it is cold. This will cause the machine to be over filled when it warms up. Wait until the machine warms up and then add enough fluid to bring the level to the full mark.

Adding only the correct fluid, and in the right amount, is important because many fluids are not compatible with each other. Incorrect fluids can severely damage or ruin a system by softening the seals or failing to blend with existing oil. This will take the machine out of service and require costly repairs. Each machine comes from the manufacturer with a recommendation about which hydraulic oil should be used. The correct oil is specified in the operation manual. Check the manual before adding oil to be sure that the oil that is to be added to the machine is among those listed by the manufacturer of the machine. Mixing oils is not recommended so stay with one brand and type of oil. Keep in mind that adding oil that has not been approved by the manufacturer of the machine will void most warranties.

Adding fluid without introducing dirt and contamination is a continuing problem. One authority goes so far as to say that the new fluid added to the system often exceeds the contamination level specified for the system, and much of this contamination is introduced while the fluid is being stored, transported, and added to the system. Fluid added to a reservoir should be pumped in through a filter. Most filter manufacturers produce filter carts for this purpose.

If bulk oil contamination is the problem, dispense the fluid directly from quart or gallon containers that are opened just before the fluid is used. To prevent contamination from the oil source, do not store partially filled oil containers.

Before filling the reservoir, clean around the fill cap with a lint-free shop towel. Make sure to add the correct fluid. Don’t pour fluid from an oil container that is not labeled. Inspect the filler screen and relief breather. If a funnel must be used, make sure it is clean. As a general rule, seamless plastic funnels collect and hold less dirt and contaminant than metal funnels. Pour only enough oil through the fill cap to bring the reservoir level to the full mark. Finally, replace the fill cap, and have a lint-free shop towel available to clean up oil that may have dripped on the machine.


Reprinted from Fluid Power Journal June/July 2020 - I found this very helpful for every day conditions.

要查看或添加评论,请登录

Steve Atchison的更多文章

  • Innovations in Hydraulic Technology: Trends and Future Prospects

    Innovations in Hydraulic Technology: Trends and Future Prospects

    Hydraulic technology has been a driving force behind various industries, providing power, control, and efficiency. As…

  • The ultimate guide to hydraulic cylinders

    The ultimate guide to hydraulic cylinders

    Hydraulic cylinders, also known as ‘hydraulic rams’, get their power from pressurized hydraulic fluid, normally…

    1 条评论
  • When to Consider a Telescopic Hydraulic Cylinder

    When to Consider a Telescopic Hydraulic Cylinder

    Deciding on the best hydraulic cylinder for your equipment can be daunting. You want to make sure that your purchase…

    1 条评论
  • The Golden Unicorn - Hyd Future

    The Golden Unicorn - Hyd Future

    Despite concerted efforts to improve its image in recent decades, hydraulics is still seen as a dinosaur by many users.…

  • Hydraulic Systems and Fluid Selection

    Hydraulic Systems and Fluid Selection

    It wasn’t until the beginning of the industrial revolution when a British mechanic named Joseph Bramah applied the…

    5 条评论
  • Fluid power’s green evolution

    Fluid power’s green evolution

    BY KEN KORANE All indications are that mobile and industrial systems of the future will be more automated and more…

  • How Big Should Hydraulic Tank Be?

    How Big Should Hydraulic Tank Be?

    When it comes to sizing a hydraulic reservoir, a motto and advice is the bigger the better. Because the greater the…

    13 条评论
  • 20 Causes of Cavitation in Hydraulic Oil

    20 Causes of Cavitation in Hydraulic Oil

    Cavitation is the term used to describe the formation of gas cavities within a liquid. In a hydraulic system, this is…

  • IS IT TIME YOU VANISHED THE VARNISH IN YOUR HYDRAULIC SYSTEM?

    IS IT TIME YOU VANISHED THE VARNISH IN YOUR HYDRAULIC SYSTEM?

    When it comes to oil condition management, varnish is a hot buzzword. But what is it? And can this one word really be…

    2 条评论
  • One-piece design is high on efficiency and reliability

    One-piece design is high on efficiency and reliability

    Original equipment manufacturers (OEMs) in construction, deep sea, off-highway, forestry and agricultural markets…

社区洞察

其他会员也浏览了