3 Safety Tips for Operating a Centrifuge

3 Safety Tips for Operating a Centrifuge

A centrifuge is an indispensable important equipment for life science research laboratories worldwide. Over the years, We have produced many types of centrifuges including high-speed refrigerated centrifuges and non-refrigerated centrifuges to meet customers' different requirements.

图片无替代文字

However, due to improper use of the centrifuge, failure to maintain the equipment regularly and inadequate technical training, Operation Failures and even accidents occur from time to time. Therefore, how to ensure the safe operation of the centrifuge and give full play to its performance is a major concern of technical and experimental personnel.


Want to improve the utilization rate and extend the service life of the centrifuge, ensure the safe operation of the instrument, and avoid failures? Heal Force Laboratory Centrifuge Correct Operation Guide and Related Precautions are as followed. Let's take a look right now!

图片无替代文字

1. Installation Steps of a Centrifuge

1) Turn on the machine and press the door key to open the centrifuge door cover.

2) Select the appropriate rotor and adapter.

3) Clean the rotor, centrifugal cavity, and adapter.

4) Install the rotor and adapter.

Notes:

图片无替代文字

① Hold the rotor with both hands and align the center hole of the rotor with the locking sleeve.

② Put it down vertically and put it on the bottom of the cone.

③ Let go of your hands, and then lightly press the rotor with your hands to confirm that the bottom of the rotor has been placed at the designated position.

④ Using the included Allen key, tighten the lock screw in a clockwise direction.


2. Instructions for Use

1) Load the centrifugal sample in the correct position.

2) Tighten the rotor cover, and slowly close the centrifuge door cover with both hands.

3) Set the parameters and start the centrifugal experiment.

4) After centrifugation, press the door button, open the door cover gently with your hand, and take out the sample.

Notes:

图片无替代文字

① Before the rotor is running, the samples and test tubes should be loaded accurately and symmetrically (need to be balanced). The centrifuge tube can be loaded with samples at different times, but the samples must be loaded symmetrically. The asymmetric loading sample chamber must never be turned on.

② When the separation sample you are using is contaminated or to prevent the separation sample from being contaminated, remove the sample and rotor from the shaft together and put it in the biological safety cabinet before performing other operations.

③ When closing or opening the door cover of the centrifuge, hold the door cover with your hand and operate it slowly and gently.

图片无替代文字

3. Clean in time after Use

1) At the end of the centrifugal experiment every day, take out the rotor and wipe the centrifuge chamber with a clean cloth.

2) Steps to take out the rotor:

① Using a special wrench to remove the rotor, loosen the locking screw in a counterclockwise direction (no need to take it out).

② Grasp the rotor with both hands, lift it up vertically, and don't shake it from side to side.

③ If you are using a horizontal rotor, first take out the centrifuge container (such as the centrifuge hanging cup).

图片无替代文字

Notes:

Wiping is mainly to remove dust, condensed water(Refrigerated Centrifuge), debris and leftovers of previously separated samples in the centrifuge chamber, and make sure that the chamber is clean and tidy.


Improper operation of the centrifuge will cause serious consequences. During the experiment, we must pay special attention to the operating specifications to ensure the correct use of the centrifuge. First-time users should consult personnel with operating experience or refer to the user manual. Remember that centrifuges should be used with care, not blindly. If you are interested in Heal Force High-Speed (Refrigerated) Centrifuges, Welcome to contact and consult us right now!?

要查看或添加评论,请登录

社区洞察

其他会员也浏览了