More than a power distribution unit, the G6 PDU monitors power and environmental conditions at the rack level. Continuously scan for electrical overloads and environmental risks to keep your IT equipment safe. Stay ahead with real time monitoring and ensure your data center's optimal performance. View the infographic to learn more: https://okt.to/4J9Cls
泛达的动态
最相关的动态
-
Energy Management Specialist | Renewable Energy Specialist | Electric Vehicle and Charging Station Specialist | Senior Electrical Engineer | Senior Low Current Engineer | MEP Manager
Emergency Standby Power (ESP) Prime Power (PRP) Limited-Time Running Prime (LTP) Continuous Power (COP) Data Center Continuous Power (DCP) Resources Generator set ratings are operating values that manufacturers provide for users, telling them how much power an engine can produce under certain conditions. These ratings are usually found on a metal plate affixed to the generator.? ?
要查看或添加评论,请登录
-
HVAC Lead,Plumbing(Freelance Consultant), Clean Room: Semiconducter, Pharma,REVIT Guide LOD 100 to 350 BIM, HAP, ELITE,Samsung,Siemens,Voltas,Detail Design Engg,MEP COORDINATER, DCIM, IBMS, DC(ISO:5-8,ISO:14644, ASHRAE )
Data Center : PUE : Power Usage Effectiveness = Total Facility Power/ IT Power of equipment DCie=Data Center Infrastructure Efficiency i. e. reciprocal of PUE. Ideal Ratio =1(power used for IT equipment. Average PUE=1.8, Aiming PUE=1.2 OR Less. ASHRAE : Data Center Temperature range 18°C to 27°C ( 64.4°F to 80.6°F), Humidity Dew Point 5.5°C to 15°C. This data helps to eliminate Hot Aisle/ Cold Aisle contaiment issue. ( Hot Aisle leaking to Cold Aisle or vice versa.) #CC2O #Netzero #HVAC #CRAC #ITRack #hotaisle #coldaisle #aireconomizer #watereconmizer #greenbuilding EM: [email protected]
要查看或添加评论,请登录
-
This previous refresh of an existing system for Yorkshire Water, involved the installation of a compressor-free cooling solution. One of the major challenges was the installation of the new solution had to be carried out and completed within a live critical facility in a data centre presenting zero risk or disruption to the site’s day-to-day operation or existing cooling infrastructure. The backup system had to remain operational as the primary cooling system was being replaced. This meant the new solution required an automatic changeover control apparatus being integrated into both the new and old systems. Read our case study... https://loom.ly/DKGzBMk #datacentresolutions #datacentrecooling #datacentreupgrade
要查看或添加评论,请登录
-
-
Importance of time synchronisation with GPS system of all protection & recording devices in power station/power systems. “When an event occurs on the power system, recorders installed at different locations may be triggered at different moments to record specific information that reflects different aspects of the same event during the course of the event. Normally, the records obtained by different recorders can be transferred to a central control office for further analysis. If different recorders are synchronized to the same time reference, then the records provided by different recorders may be correlated with each other to reconstruct the event and thus provide a clearer and more complete picture of the entire event. The input data that may be needed for analyzing the event usually include both analog data such as phase currents, residual current, phase voltages, and residual voltage and digital data such as primary and backup relay trip, breaker open/close position, breaker failure contact, carrier start, and carrier received contacts, etc.”
要查看或添加评论,请登录
-
DC Manager - STT Global Data Centres India Private Limited | EXIN EPI CDCP? | ETAP | Load flow | Harmonic Analysis
?? A Day in Data Centre Series - Part 2- Sec-10: Having trouble choosing between air insulated and sandwich busbar trunking for your next project? Busbar trunking systems offer a safe and efficient way to distribute power, but selecting the right type can be crucial. In this post, I break down the key differences between air insulated and sandwich busbar trunking, including their: ?? Insulation methods ?? Current ratings ? ?? Size considerations ?? Suitability for different environments #ElectricalEngineering #PowerDistribution #BusbarTrunking #IndustrialElectrical
要查看或添加评论,请登录
-
-
DC Manager - STT Global Data Centres India Private Limited | EXIN EPI CDCP? | ETAP | Load flow | Harmonic Analysis
?? A Day in Data Centre Series - Part 1- Sec-19: ?? Comparing Protection in Oil & Dry-Type Transformers ? While their core function remains the same, their protection needs differ. Let's delve into the key protectors safeguarding these vital components: #oiltransformers #drytypetransformers #protectionrelays #differentialprotection #buchholzrelay #overheatingprotection #lightningprotection #earthing #groundfaults #powerdistribution #industrialmaintenance
要查看或添加评论,请登录
-
-
Effective power and cooling management will help to improve data centre efficiencies by optimizing spare, idle, safety margin and stranded capacities
要查看或添加评论,请登录
-
How industries can mitigate the impact of power outages and maintain optimal productivity ? 1. Investing in backup power systems, such as generators and UPS. 2. Conducting regular power audits. 3. Developing a comprehensive emergency response plan. 4. Implementing remote monitoring and telemetry.
要查看或添加评论,请登录
-
Improve your electrical distribution assets' safety and resiliency by transitioning from a paper-based single-line diagram (SLD) to a digital platform. It allows your SLD to become a dynamic tool. Discover more insights in our blog. https://spr.ly/6044RvZgM #AuditReport #ElectricalSafety #LifeIsOn
要查看或添加评论,请登录
-
-
Uncover the significance of PUE for efficiency mastery. Explore Electrical Maintenance Safety Devices as your shield against downtime and reputation risks. Strengthen your Data Centers! ?? #PUEEfficiency #DataCenterFortification ?? https://iriss.com/ ?? 941-907-9128 #IRISSSafetySolutions #ReliableAssets #AssetMonitoring #InspectionSolutions #CriticalAssetManagement #IndustrialSafety #ConditionMonitoring #AssetIntegrity #RiskMitigation #PredictiveMaintenance #SafetyFirst #AssetReliability #EquipmentInspection #MaintenanceManagement #IndustrySafetyStandards #safety #reliability
要查看或添加评论,请登录
-